3 ADJUST HOT LIMIT STOP
HOT LIMIT SAFETY STOP ADJUSTMENT
By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP.
Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT SAFETY STOP (1). Follow Step "A" or "B" to adjust min./max. discharge temperature. "0" being the hottest to "7" the coldest temperature setting. Factory set at "0".
"RED RING"- HOT LIMIT SAFETY STOP
1
"A"
|
|
|
|
|
| 6 |
|
|
|
|
| 5 |
|
| 0 | 1 | 2 | 3 | 4 |
|
"A" |
|
|
| |||
|
|
|
|
| "B" "B" | |
ADJUSTMENT WHEN |
|
|
|
|
| |
WATER IS TOO HOT |
|
|
|
|
| ADJUSTMENT WHEN |
|
|
|
|
|
| |
PRY RED RING |
|
|
|
|
| WATER IS TOO COLD |
TEMPERATURE |
| |||||
FORWARD AND ROTATE | PRY RED RING | |||||
SETTING |
| FORWARD AND | ||||
ONE CLICK | NUMBERS | ROTATE CLOCKWISE |
4 | HANDLE INSTALLATION | 4a INSTALL ADAPTER SCREW |
INSTALL HANDLE ADAPTER |
Push HANDLE ADAPTER (1) onto VALVE STEM (2). Tighten set screw (3) with 2.5mm hex wrench supplied.
2
1
3
2.5MM HEX WRENCH
4b INSTALL ADPATER
With a flat blade screwdriver thread ADAPTER (5) onto SET SCREW (4) and tighten.
5
4
With a flat blade screwdriver thread ADAPTER SCREW (4) into HANDLE STEM ADAPTER (1) and tighten.
1
4
4c INSTALL HANDLE
Align HANDLE (6) and install onto
HANDLE ADAPTER ASSEMBLY (7). Tighten set screw (8) with 2.5mm
hex wrench supplied to secure HANDLE.
Push PLUG BUTTON (9) into set screw access hole in HANDLE (6).
7
8
9
6
2.5MM HEX WRENCH
5 SERVICE
If faucet drips, operate handle several times from "off" to "on". Do not apply excessive force.
Clogged CARTRIDGE (4) inlets may cause reduced flow in "full on" hot or cold. To clean inlets, first turn off water supply, then:
Remove HANDLE (1), CAP (2) and CARTRIDGE (4). Clean inlets and MANIFOLD (5).
Reassemble CARTRIDGE (4), alternately tightening SCREWS (3). Replace CAP (2) and HANDLE (1). Check flow.
5
4
CARTRIDGE
INLETS
3
2
1
M968951 Rev. 1. 4