3 ADJUST HOT LIMIT STOP

3 ADJUST HOT LIMIT STOP

HOT LIMIT SAFETY STOP ADJUSTMENT

By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold, the HOT LIMIT SAFETY STOP reduces risk of accidental scalding. To set the maximum hot water temperature of your faucets, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP.

HANDLE INSTALLATION4a INSTALL ADAPTER SCREW Use a flat blade screwdriver or your fingers to pull up and rotate red HOT LIMIT SAFETY STOP (1). Follow Step "A" or "B" to adjust min./max. discharge temperature. "0" being the hottest to "7" the coldest temperature setting. Factory set at "0".

"RED RING"- HOT LIMIT SAFETY STOP

1INSTALL HANDLE ADAPTER4b INSTALL ADPATER4c INSTALL HANDLE5 SERVICEManual background

"A"

 

 

 

 

 

 

6

 

 

 

 

 

5

 

 

0

1

2

3

4

 

"A"

 

 

 

 

 

 

 

 

"B" "B"

ADJUSTMENT WHEN

 

 

 

 

 

WATER IS TOO HOT

 

 

 

 

 

ADJUSTMENT WHEN

 

 

 

 

 

 

PRY RED RING

 

 

 

 

 

WATER IS TOO COLD

TEMPERATURE

 

FORWARD AND ROTATE

PRY RED RING

COUNTER-CLOCKWISE

SETTING

 

FORWARD AND

ONE CLICK

NUMBERS

ROTATE CLOCKWISE

4

HANDLE INSTALLATION

4a INSTALL ADAPTER SCREW

INSTALL HANDLE ADAPTER

Push HANDLE ADAPTER (1) onto VALVE STEM (2). Tighten set screw (3) with 2.5mm hex wrench supplied.

2

1

3

2.5MM HEX WRENCH

4b INSTALL ADPATER

With a flat blade screwdriver thread ADAPTER (5) onto SET SCREW (4) and tighten.

5

4

With a flat blade screwdriver thread ADAPTER SCREW (4) into HANDLE STEM ADAPTER (1) and tighten.

1

4

4c INSTALL HANDLE

Align HANDLE (6) and install onto

HANDLE ADAPTER ASSEMBLY (7). Tighten set screw (8) with 2.5mm

hex wrench supplied to secure HANDLE.

Push PLUG BUTTON (9) into set screw access hole in HANDLE (6).

7

8

9

6

2.5MM HEX WRENCH

5 SERVICE

If faucet drips, operate handle several times from "off" to "on". Do not apply excessive force.

Clogged CARTRIDGE (4) inlets may cause reduced flow in "full on" hot or cold. To clean inlets, first turn off water supply, then:

Remove HANDLE (1), CAP (2) and CARTRIDGE (4). Clean inlets and MANIFOLD (5).

Reassemble CARTRIDGE (4), alternately tightening SCREWS (3). Replace CAP (2) and HANDLE (1). Check flow.