Replacement Parts
Replacement parts may be ordered through your plumber or the local distributor. Parts will be shipped at prevailing prices and billed accordingly. When ordering replacement parts, always have the following information ready:
1.model, serial, and product number
2.type of gas
3.item number
4.parts description
See “Repair Parts” section.
Removing the Burner/Manifold Assembly
1. Turn off the gas to the water heater at the manual gas
figure 2), and disconnect power to the water heater.
2.Remove the outer door.
4.Remove the 2 screws securing the manifold door assembly to the skirt.
5.Disconnect the hot surface igniter/flame sense wire and manifold tube at the thermostat.
(Figure 16) NOTE: L.P. |
|
|
gas systems use reverse |
|
|
Manifold | Hot Surface | |
manifold tube. | ||
6. Grasp the manifold tube | Tube | Igniter/Flame |
| Sense Connector |
and push down slightly to
free the manifold from the gas control valve/ thermostat.
7.Carefully remove the manifold assembly from the burner compartment. Be sure not to damage internal parts.
8.Check the burner to see if it is dirty or clogged. The burner may be cleaned with soap and hot water.
Removing the Burner from the Manifold Assembly
1.Take off the burner by removing the two (2) screws located underneath the burner.
2.Check the burner to see if it is dirty or clogged. The burner may be cleaned with soap and hot water. See Figure 17.
FIGURE 17
Natural & L.P. Gas Burner Assembly
Manifold Door Gasket
Two Piece Wire | Manifold Door Assembly |
Connector | Flame Sense/Hot |
Burner | |
Flame Sense | Surface Igniter Wire |
Hot |
| Surface | Manifold |
|
| Tube |
| ||
Igniter |
|
| ||
|
|
|
| Flame Sense/Hot |
Manifold Door Assembly | Surface Igniter Wire | |||
| ||||
Burner |
| Manifold Tube | ||
|
|
|
| |
|
|
|
| Viewport |
19