Installation (Locating The Water Heater) continued-

The water heater must be located close enough to the outside wall to keep the venting distance within the maximum distance described in the installation instructions. Note: The direct vent-air intake terminal must be installed on a vertical wall. Read the venting section in this installation instruction manual before locating the water heater.

This water heater must be located in an area where leakage of the tank or water line connections and the combination temperature and pressure relief valve will not result in damage to the area adjacent to the water heater or to lower floors of the structure. When such locations cannot be avoided, a suitable drain pan, adequately drained, must be installed under the water heater. The pan must not restrict combustion airflow. The drain pan must have a minimum length and width of at least 4 in. (10.2 cm) greater than the diameter of the water heater and must not restrict proper combustion air flow to the water heater. The drain pan, as described above, can be purchased from your plumbing professional. The drain pan must be piped to an adequate drain. The piping must be at least 3/4 inch (1.9 cm) in diameter and pitched for proper drainage.

It is recommended that a minimum clearance of four (4) inches (10.2 cm) be provided on the side of the water heater for servicing and maintenance of the combination temperature and pressure relief valve.

MINIMUM CLEARANCES

WARNING

Failure to adhere to these installation and operating instructions may create a hazard to life and property and will nullify the warranty.

This installation shall allow access to the front of the water heater and adequate clearance shall be provided for servicing and operating this water heater. The water heater may be installed on either a combustible or non-combustible floor. If the water heater is to be installed directly on carpeting, it shall be installed on top of a metal or wood panel extending beyond the full width and depth of the appliance by at least three (3) inches (76.2 mm) in any direction or, if the appliance is to be installed in an alcove or closet, the entire floor shall be covered by the panel. The minimum clearances to combustibles for this water heater is: zero (0) inch (0 cm) from the sides and rear, four (4) inches (10.2 cm) from the front of the jacket, zero

(0)inch (0 cm) from the plenum, zero (0) inch (0 cm) from the air intake elbow and telescopic tubes and twelve (12) inches (30.5 cm) from the direct vent-air intake terminal. (See Figure 1).

8

Page 8
Image 8
American Water Heater DIRECT VENT GAS WATER HEATER instruction manual Minimum Clearances

DIRECT VENT GAS WATER HEATER specifications

The American Water Heater Direct Vent Gas Water Heater is designed to provide efficient and reliable hot water for residential needs. This innovative appliance combines advanced technologies with user-friendly features, making it an excellent choice for homeowners seeking an optimal balance of performance, safety, and convenience.

One of the standout features of the American Water Heater Direct Vent Gas Water Heater is its direct venting system. This technology allows the unit to draw combustion air from the outside while safely venting exhaust gases directly outside. This eliminates the need for indoor air, making it an ideal solution for highly insulated homes or those with limited indoor air supply.

The unit's delivery of a fast recovery rate ensures that hot water is always available when needed. It utilizes a powerful burner system that generates a high BTU (British Thermal Unit) output, allowing for quicker heating of water. This feature is particularly beneficial during peak usage times when multiple hot water outlets are in use simultaneously.

Safety is a priority with this water heater, which is equipped with a variety of built-in safety features. The flame rollout switch, for instance, serves as a safeguard against overheating, while the integrated gas shut-off valve provides an additional layer of protection against gas leaks. These features ensure peace of mind for users, knowing that their water heater is designed with safety in mind.

In terms of energy efficiency, the American Water Heater Direct Vent Gas Water Heater complies with the latest energy standards. Its efficient design and advanced insulation help minimize heat loss, resulting in reduced energy consumption and lower utility bills. Homeowners benefit from energy savings without sacrificing hot water performance.

Maintenance of the unit is straightforward, thanks to its accessible design. Regular maintenance can extend the life of the water heater, ensuring optimal performance for years to come. Many models come with the option of a maintenance-free anode rod, further simplifying upkeep.

Another appealing characteristic is the water heater’s compact design, which allows for flexible installation options, even in tight spaces. This versatility makes it suitable for various applications, from basements and garages to utility closets.

In summary, the American Water Heater Direct Vent Gas Water Heater stands out for its combination of efficiency, safety, and convenience. With its advanced direct vent technology, rapid recovery rate, and robust safety features, it meets the demands of modern homes while providing reliable hot water solutions. Whether you are upgrading an existing system or installing a new water heater, this model is worth considering for its impressive performance and user-friendly design.