Residential Gas High
96% THERMAL EFFICIENCY CONTINUOUS HOT WATER VERSATILE POWER DIRECT VENT
CODES AND STANDARDS
•
•This model meets or exceeds the thermal efficiency and standby loss requirements of the U.S. Department of Energy and current edition ASHRAE/IESNA 90.1
|
|
| FIRST HOUR | RECOVERY |
|
| DIMENSIONS |
|
|
| ||
MODEL | BTU | GALLONS | DELIVERY | GALLONS |
|
| INCHES/CENTIMETERS |
|
| SHIPPING WEIGHT | ||
INPUT | OR | GALLONS | OR |
|
|
|
|
|
| |||
NUMBER* | PER HOUR | LITRES | OR | LITRES | A | B | C | D | E | F | LBS/KG | |
|
| |||||||||||
|
|
| LITRES | 90°F/50°C RISE |
| |||||||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| |
VG6250T100NV | 100,000 | 50 | 164 | 129 | 22 | 3 | 8 | 255 | ||||
|
|
|
|
|
|
|
|
|
| |||
189 | 621 | 488 | 169.55 | 125.09 | 55.88 | 40 | 7.62 | 20.32 | 115.7 | |||
|
|
Inlet and outlet connections: 3/4” male
Circulation loop connections: 3/4” female Gas inlet:1/2”
Maximum Supply Pressure: 14 inches W.C. (3.48kPa)
Minimum Supply Pressure for Natural Gas: 3.50 inches W.C. (.87kPa)
Minimum Supply Pressure for Propane Gas: 8.00 inches W.C. (1.99kPa) Minimum pressure must be maintained under both load and no load
(dynamic and static) conditions.
Electrical Characteristics - 120V, 60Hz, Amperes <5 * Available in LP - Change N to P when ordering.
3” DIAMETER
PVC VENT/EXHAUST
1 3/16” 4 1/2” DIAMETER
1 1/2”
*21 1/8”
3” DIAMETER PVC INTAKE/COMBUSTION AIR
**39”
OPTIONAL CONCENTRIC VENT KIT
Residential gas water heater(s) shall be models ____________ as manufactured by American Water Heaters, or an approved equal, and shall have a ______
warranty and a ______
input of __________ BTUs, and shall be designed, tested and listed with CSA International in accordance with the latest edition of ANSI Z21.10.1 - CSA4.1 standard.
1992. The interior of the storage tank shall be lined with a Fused Ceramic Shield lining, fused to the tank at 1600° F, forming a
| Distributed By: |
Order Entry and Sales | Warranty and Service |
500 Princeton Road (FEDEX, UPS) | 500 Princeton Road (FEDEX, UPS) |
Johnson City, TN | Johnson City, TN |
P.O. Box 4808 (Mailing) | P.O. Box 1597 (Mailing) |
Johnson City, TN | Johnson City, TN |
(800) | (800) |
FAX (800) | FAX (800) |
| NRGSS01210 Revised August 2010 |
No part of this work may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or by any information storage retrieval system, without permission in writing from American Water Heaters.