Operator Control Station

ELECTRICAL FEATURES

NEMA 12 painted steel operator panel contains the following:

-Allen Bradley push buttons for the following functions:

-Start

-Stop

-Jog

-Manual air blast

-Alarm, acknowledge, reset

-Emergency stop

-Speed pot

-Speed indicator

NEMA 12 machine mount painted steel electrical enclosure including:

-Main disconnect switch

-Allen Bradley MicroLogix 1100 Modular hardware programmable logic controller with Ethernet communication and online edition

-Allen Bradley PowerFlex AC inverter 3 HP with brake resistor

-Incremental encoder for scoop position

110V outlet and power for closer and labeler

Sensor for bag detection

Double loaf detector

Interlocks on all doors

SPECIFICATIONS

Throughput range:

Approximate shipping weight:

35 - 60 loaves per minute

2,500 lb. (1134 kg)

Electrical requirements:

Approximate dimensions:

Main Power - 6 KVA

104” x 127” x 60”

Control Power - 24 VDC/120 VAC

(2642 mm x 3226 mm x 1524 mm)

Air Requirements - 6 SCFM @ 80 PSIG

 

Loaf size range:

 

Length: 8” (203 mm) - 16” (406 mm)

 

Width: 3-5/8” (92 mm) - 5-1/2” (140 mm)

 

Height: 3” (76 mm) - 6” (152 mm)

 

 

 