10 11
Sizing charts based on:
• Precharge matched to incoming supply
pressure prior to installation
• Incoming water temperature 40°F
• 150psi T & P safety relief valve
AMTROL’s Therm-X-Trol®brochure MC#4090
contains precise sizing guidelines for sytems not
covered in the above charts.
The thermal-expansion tank for domestic waterheaters, sized right, is the only logical answer to thegrowing problem of thermal expansion in waterheaters protected by BFP, check valves or pressure-reducing valves. A simple installation to the supplyside on the water heater, this small tank will eliminatethe dangerous condition so that the relief valve will notopen during normal heating cycles.
BACK FLOW PREVENTER
BFP
Water Heater*
Size (gals.)
Static Supply Pressure (psi)
**
40 ST-5 ST-5 ST-5
50 ST-5 ST-5 ST-5
60 ST-5 ST-5 ST-8
80 ST-8 ST-8 ST-12
120 ST-12 ST-12 ST-25V
40 60 80
Max. Temp. Setting 140°F
Water Heater*
Size (gals.)
Static Supply Pressure (psi)
**
40 ST-5 ST-5 ST-5
50 ST-5 ST-5 ST-8
60 ST-8 ST-8 ST-8
80 ST-8 ST-8 ST-12
120 ST-12 ST-12 ST-25V
40 60 80
Max. Temp. Setting 150°F
Water Heater*
Size (gals.)
Static Supply Pressure (psi)
**
40 ST-8 ST-8 ST-8
50 ST-8 ST-8 ST-12
60 ST-8 ST-12 ST-25V
80 ST-12 ST-25V ST-25V
120 ST-25V ST-25V ST-25V
40 60 80
Max. Temp. Setting 180°F