CB-TP5Rough-In Box for 5" Wall/Flush Mount Touch Panels

Overview

The CB-TP5 Rough-In Box is an optional accessory for 5” Modero® Wall/Flush Mount Touch Panels. The Rough-In Box allows the panel to be mounted directly to the studs/ pre-wall and includes a wall box and mounting screws.

Wall Mount panels (NXDs) are contained within a metallic outer housing (back box). This back box is not removed when installing the NXD into a Rough-In Box. The back box is only removed to gain access for the replacement of the Compact Flash component or upgrade to the VESA housing.

Specifications

CB-TP5 (FG038-10) Specifications

Dimensions (HWD)

• 3

3/4" x 5 1/4" x 3 3/8"

 

• 9.6 cm x 13.3 cm x 8.6 cm

 

 

 

Included

• 4

Phillips pan-head (#4-40 x 0.375 Black) screws (80-0115)

Accessories

4

Phillips pan-head (#4-40 x 0.625 Black) screws (80-0118)

 

 

 

Certifications

cTUVus Listed

 

 

 

 

WARNING: INSTALLER, LEAVE A GAP BETWEEN THE STUD AND ROUGH-IN BOX TO ACCOMMODATE THE DRYWALL/SHEETROCK.

This gap allows the installation of the drywall/sheetrock after the CB-TP5 has been mounted onto the beams. The rough-in box installation must be done prior to any wall installation.

Note: The most important thing to remember when mounting this rough-in box is that the mounting tabs must be mounted flush against the outside of the sheetrock.

It is recommended that you cut out the surface slightly smaller than what is outlined in the installation drawings so that you can make any necessary cutout adjustments.

The wiring knockouts on the left side will be used for the NXD-CV5 Wall Mount panel connectors, so always secure the rough-in box to the stud using the Stud Mounting Holes on the right side of the box.

Pre-Wall Installation of the CP-TP5 Rough-In Box

Refer to the SP226101 diagram for detailed installation dimensions.

Cutting out the surface slightly smaller than what is outlined in the installation drawings, in order to make any necessary cutout adjustments, is highly recommended.

The wiring knockouts on the left side will be used for the NXD-CV5 Wall Mount panel connectors, so always secure the rough-in box to the stud using the Stud Mounting Holes on the right side of the box.

1.Rest the right Stud Mounting tabs onto the stud (keeping the knockouts on the left). Be sure to leave enough of a gap between the stud and NXD Mounting tabs to accommodate the installation of the drywall or sheetrock after the rough-in box has been mounted. Ultimately, the Mounting Tabs should lie flush against the outside of the sheetrock.

2.Fasten the CB-TP5 rough-in box to the stud through the holes on the right Stud Mounting tabs (FIG. 1), using either nails or screws.

 

 

Rough-In Box

 

Do Not Use these

 

 

 

Stud

tabs to mount

 

 

 

 

 

the Rough-In Box

 

 

 

6X Knockout for 1/2” conduit fitting

Front surface of mounting tabs should be flush with outside face of drywall

Drywall

FIG. 1 CB-TP5 - Drywall Installation

3.Remove the wiring knockouts from the left side of the CB-TP5 to accommodate the cables being threaded through to the NXD touch panel.

Note: Remember that when mounting this rough-in box, the NXD mounting tabs must lie flush against the outside of the sheetrock.

4.Thread the incoming power, RJ-45 audio/video, Ethernet, and USB wiring through the knockouts (use of the left wiring knockouts are recommended with this installation). Leave enough slack in the wiring to accommodate any re- positioning of the panel.

5.Install the drywall/sheetrock before inserting the main NXD unit into the CB-TP5.

Recommended Cutout for CB-TP5 Rough-In Box

Page 1
Image 1
AMX CB-TP5 specifications Rough-InBox, Do Not Use these, Stud, tabs to mount, 6X Knockout for 1/2” conduit fitting

FAQ

What is the purpose of the CB-TP5 Rough-In Box?

The CB-TP5 Rough-In Box is an optional accessory for 5 Modero Wall/Flush Mount Touch Panels, allowing for direct mounting to studs/pre-wall and including a wall box and mounting screws.

What should be considered when mounting the rough-in box?

Installers should leave a gap between the stud and the rough-in box to accommodate the drywall/sheetrock, and ensure the mounting tabs are flush against the outside of the sheetrock.

How should the wiring be handled during installation?

The wiring knockouts on the left side of the CB-TP5 should be used for the NXD-CV5 Wall Mount panel connectors, and enough slack in the wiring should be left to accommodate re-positioning of the panel.