RDM-2INC Dual Incandescent Dimmer Module 2400 W (x2)
The
Mounting points
Line in (hot)
Line out
350 µS choke
Dual 20 A power device
FIG. 1 RDM-2INC
•120 VAC, 50/60 Hz, 2400 W
•240/277 VAC, 50/60 Hz, 2400 W
Suggested Dimmed Loads
•Incandescent
•
•Neon,
•
Specifications
•AC lighting loads only.
•For indoor use only.
•This module may require extra power from the AXlink connection or an external power supply connected to the control card.
Connecting the RDM-2INC to the AMX Lighting Master
Pin 4 (GND)
Pin 3 (RLY)
Pin 2 (DIM)
Pin 1 (+12 V)
2
1(+)
Note: The
FIG. 2 RDM-2INC connections
Lighting Application Drawing
(B) Neutral
(A) Neutral |
| |
(B) Line in (HOT) | (B) Load | |
(A) Line in (HOT) | (A) Load | |
| Light A Light B | |
Circuit breaker | Neutral | |
panel | ||
Load | ||
|
Neon lights
Neutral
Load
FIG. 3 RDM-2INC wiring application
•Dimensions (HW): 10.0" x 2.75" (25.4 cm x 6.99 cm)
•Phase dependant
•Use wires rated at 75°C (167°F)
•Torque terminals to 7
•Max. wire size: 10 AWG (4 mm²)
•Wire stripping length: 0.28" (7 mm)
•Weight: 6.5 lbs. (2.948 kg)
•BTU/hr: 600
•Control current: 45 mA @ 12 VDC per dimmer, 90 mA total
Caution:
•All Class 1 wiring must be connected to proper terminals.
•All control wiring must be connected to proper temrnials.
•Disconnect power while installing or connecting the unit.
•Keep top and bottom air vents clear at all times.
•Test loads for shorts before connecting.
•Use low voltage wires with a 300 volt rating or greater.
•Use field installed copper conductors.
•Run all
•Each dimming circuit must have a separate neutral connection.