Installation Sheet
RDM-INC50 Incandescent Dimmer Module 6000 W
The
Mounting points
Line in (hot)
Load out
500µS choke
50 A Power
Device
•All electrical ratings are for continuous duty.
•AC lighting loads only.
•For indoor use only.
•This module may require extra power from the AXlink connection or an external power supply connected to the control card.
Connecting the RDM-INC50 to the AMX Lighting Master
Pin 4 (GND)
Pin 3 (RLY)
Pin 2 (DIM)
Pin 1 (+12 V)
2
1(+)
Note: The
FIG. 2 RDM-INC50 connections
Lighting Application Drawing
| All neutrals are common to the |
| Neutral block in the enclosure. |
| Provide a separate neutral for |
Neutral | each load. |
|
Line in (HOT) | Load |
|
FIG. 1 RDM-INC50
•120 VAC, 6000 W
•240/277 VAC, 6000 W
Suggested Dimmed Loads
•Incandescent
•
•Neon, cold cathode
•
Specifications:
•Dimensions (HW): 10.0" x 5.50" (25.4 cm x 13.97 cm)
•Phase dependant
•Use wires rated at 75°C (167°F)
•Torque terminals to 16
•Max. wire size: 8 AWG (10 mm²)
•Wire stripping length: 0.28" (7 mm)
•Weight: 7.0 lbs. (3.175 kg)
•BTU/hr: 750
•Control current: 45 mA @ 12 VDC
•Occupies two enclosure spaces
Caution:
Neutral
Load
FIG. 3 RDM-INC50 wiring application
Neutral
Load
Neon lights
(cold-cathode, on/off)
•All Class 1 wiring must be connected to proper terminals.
•All control wiring must be connected to proper terminals.
•Disconnect power while installing or connecting the unit.
•Keep top and bottom air vents clear at all times.
•Test loads for shorts before connecting.
•Run all control and
•Each dimming circuit must have a separate neutral connection.
•Use
•Use field installed copper conductors.