When the battery is completely discharged the LCD will flash the 15 minute icon and the ‘RES’ bar until the battery is returned to a charger.

If the protection electronics detect a low battery voltage condition (any one cell reaches roughly 2.5Vdc or approximately 10V battery voltage), the LCD sidebars will flash until the battery is returned to a charger. If the battery is not returned to the charger, after a time the Fuel Gauge will be turned off and the LCD will go completely blank until the battery is returned to a charger.

LCD ICON’s

 

Indication

Action

- Side Bar blinking

 

Learn

Full Discharge,

- Any others on normally

 

 

then Charge

 

 

 

 

- Side Bar blinking

 

Over Current

Remove

- Any others lit and blinking

 

 

Excess Load

- Side Bar lit, but NOT

 

Under

Return to

blinking

 

Voltage

Charger

- All others off

 

 

 

- Display blank

 

Under

Return to

 

 

Voltage

Charger

 

 

 

 

 

10

 

Page 12
Image 12
Anton/Bauer 90 owner manual LCD ICON’s Indication Action