Back-UPS® Pro Battery Pack
Installation and Operation
Installation
| |
bu149a | bu0151a |
Battery Maintenance and Storage Guidelines
Please follow these Guidelines to get the best performance possible from your UPS.
1.Keep the UPS in a cool location.
2.Turn the UPS OFF when connected equipment is not in use. If the connected equipment will not be used for a long period of time, turn the UPS OFF to preserve the battery.
3.Manage UPS Shut down in regions having frequent outages. Promptly save your files and shut down your computer at the onset of a power outage to preserve battery life and reduce recharge time. If the UPS was supplied with
a computer cable, you can automate this process by down loading and configuring PowerChute® software.
4.Replace the battery after extended storage. If it is not possible to recharge the stored UPS battery following 6 months of storage, it is recommended to purchase a genuine APC Replacement Battery Cartridge (APCRBC) to maintain optimal performance of the UPS. Note: APC's UPS inventory policy is to recharge the UPS before storage causes loss of run time performance.
5.Battery wear and warranty. Eventually, the battery will become worn from use and require replacement. Normal battery wear is not covered by the Limited Warranty.
Contact APC to purchase a genuine APC Replacement Battery Cartridge (APCRBC).
Contact Information
Technical Support | http://www.apc.com/support |
Worldwide | +1 |
Specifications
Model | BR24BPG |
Battery Voltage | 24 Vdc (nominal) |
Typical Recharge Time | 24 hours |
Operating Temperature | 0o to 40oC (32o to 104oF) |
Storage Temperature | |
Operating / Storage | 0 to 95% |
Relative Humidity |
|
Size (H x W x D) | 30.1 x 11.2 x 38.2 cm |
| (11.9 x 4.4 x 15 in) |
Weight | 13.4 kg (29.5 lb) |
Shipping Weight | 14.6 kg (32.2 lb) |
Limited Warranty
The standard warranty is three (3) years from the date of purchase. (Valid in U.S., Canada, and European Community only. For all other regions, the standard warranty is two (2) years from the date of purchase). APC’s standard procedure is to replace the original unit with a factory reconditioned unit. Customers who must have the original unit back due to the assignment of asset tags and set depreciation schedules must declare such a need at first contact with an APC Technical Support representative. APC will ship the replacement unit once the defective unit has been received by the repair department, or
Customer support and warranty information is available at the APC Web site, www.apc.com.