| Automatic Voltage Regulator |
www.apc.com | Models LE600 and LE1200 |
|
Thank you for purchasing APC’s
The
Applications
CAUTION: The total power consumption of all equipment plugged into the
The
Appliances not suitable for use with the
Installation
•Placement - Please install the
Do not block the top or side air vents on the unit. Allow 1 inch (2.5 cm) minimum vent clearance.
2.5 cm (1 inch)
• Select Input Voltage - The |
Switch for adjusting the input voltage for the region where it is being used (example: Mexico |
Limited Warranty
American Power Conversion (APC) warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its sole option, any such defective products. To obtain service under warranty you must obtain a Return Material Authorization (RMA) number from APC or an APC service center. Products must be returned to APC or an APC service center with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase. This warranty does not apply to equipment which has been damaged by accident, negligence, or misapplication or has been altered or modified in any way. This warranty applies to the original purchaser who must have proper registered the product within 10 days of purchase.
EXCEPT AS PROVIDED HEREIN, AMERICAN POWER CONVERSION MAKES NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTIBILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some countries do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser.
EXCEPT AS PROVIDED ABOVE, IN NO EVENT SHALL APC BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, APC is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise. This warranty gives you specific legal rights and you may also have other rights which may vary from location to location.
Contact Information
Technical Support | http://www.apc.com/support |
Features
Lights when input voltage is high.
Flashes when input voltage is above rated Input Voltage Range.
Input voltage is normal.
Lights when input voltage is low.
Flashes when input voltage is below rated Input Voltage Range.
ON/OFF Power Switch/Circuit Breaker applies and removes power to/from the
AC Outlets (4)
(connect equipment here)
AC Plug
(to wall outlet)
ON/OFF
Power Switch/
Circuit Breaker
Transformer
Block AC
Outlet
Building Wiring Fault Indicator (see Plug the
User Selectable Voltage Switch
(see Select Input Voltage)
- 127V, United States - 120V, or Jamaica - 110V). Slide the switch to select the proper |
voltage for your location. |
• Plug the |
Building Wiring Fault Indicator is lit, the building wiring presents a potential shock hazard |
and should be serviced by a qualified electrician before putting this device into service. The |
by fuses or circuit breakers. |
• Connect Your Equipment - Plug equipment into the |
the equipment ON. The equipment will not be powered until the |
CAUTION: The total power consumption of all equipment plugged into the |
exceed the ratings listed in the Specifications table below. A total load in excess of the listed |
ratings will cause the ON/OFF power switch/circuit breaker to “trip”. |
• Switch ON the |
ON (l) position. This switch may be used as the master ON/OFF switch for the device and all |
equipment connected to the unit. |
Specifications
Characteristics | Model LE600 |
| Model LE1200 |
|
|
|
|
Maximum Output Power | 600 W or 600 VA |
| 1200 W or 1200 VA |
Capacity |
|
|
|
Nominal Output Voltage | 110, 120, or 127 | (User Selectable) | |
Nominal Input Current | 5 A |
| 10 A |
Input Voltage Range | 80 - 130V (Selector | Switch set to 110V) | |
| 85 - 140V (Selector Switch set to 120V) | ||
| 90 - 150V (Selector Switch set to 127V) | ||
|
|
| |
Maximum Input Voltage |
| 250V | |
Surge Energy |
| 702 Joules | |
Output Regulation |
| +6 to | |
Response Time | < 2 AC Cycles | ||
Efficiency |
| >93% |
Internet | http://www.apc.com |
|
|
North America | 1.800.800.4APC |
|
|
Mexico | 292.0253 / 292.0255 |
|
|
Worldwide | +1.401.789.5735 |
ON/OFF Power Switch/Circuit Breaker
The
Nominal Frequency |
| 50/60 Hz |
Number of Outlets |
| 4 |
Operating Temperature | 32 - 104°F (0 - 40°C) | |
Relative Humidity | 0 - 95% | |
Dimensions | 4.6 x 8.4 x 5.5 inches (118 x 214 x 141 mm) | |
Weight | 7.25 lb (3.3 kg) | 9.7 lb (4.4 kg) |