User Guide - SurgeArrest® Power-Saving Surge Protector P7GB/P8GT
Complete and return the warranty card.
Read the safety instructions before installing the unit. Failure to follow these instructions may cause damage to equipment.
•The SurgeArrest is intended for indoor use only. The internal components are not sealed from the environment.
•Do not install the SurgeArrest where there is excessive heat or humidity.
•Do not use extension cords with the SurgeArrest.
•Plug the SurgeArrest into a three wire, grounded receptacle only. If the Building Wiring Fault LED illuminates indicating a wiring fault, discontinue use and have a qualified electrician check the building wiring for an overloaded neutral, reversed polarity, or amissing ground.
•Never install electrical wiring during a lightening storm.
•If the SurgeArrest is to be used for telephone protection, connect only on standard two wire “dial up” telephone service.
Overview and Operation
ALWAYS ON
Auto/Manual
•Move the switch to Auto to enable the MASTER and CONTROLLED by MASTER features.
•Move the switch to Manual to disable the MASTER and CONTROLLED by MASTER feature. The MASTER and CONTROLLED by MASTER outlets will continue to receive power until the unit is unplugged for the wall outlet.
MASTER and CONTROLLED by MASTER
•Connect a computer, laptop or netbook to the MASTER outlet.
•Connect the peripherals (monitor, scanner, or speakers), to the CONTROLLED by MASTER outlets.
NOTE: Standby or hibernation mode must be enabled. For Windows, access Control Panel, select Power Options then select Power Schemes. For MacIntosh, access System Preferences then select Energy Saver.
NOTE: Some computers consume so much power that the MASTER outlet does not recognize standby or hibernation mode. In this case the CONTROLLED by MASTER outlets will not shut off power to peripheral equipment.
NETBOOK PC/NB slider
Circuit Breaker
Telephone line surge protection jacks P8GT models
•Connect the telephone line from the wall outlet to the SurgeArrest receptacle labeled IN.
•Connect one end of the telephone patch cable (supplied), to the receptacle labeled To Equipment. Connect the other end of the cable to the DSL modem or FAX machine.
PROTECTION WORKING
BUILDING WIRING FAULT
P7GB
•
RESEST
PROTECTION | WORKING |
BUILDING | WIRING FAULT |
ALWAYS ON OUTLETS
NETBOOK PC/NB
|
|
|
|
|
|
|
|
MASTER | CONTROLLED BY MASTER |
P8GT
•
srg003a | WORKING |
| PROTECTION |
MASTER
| AUTO |
BUILDING WIRING FAULT | MANUAL |
OUTLETS ON ALWAYS |
|
To Equipment | In |
srg004a
RESEST NETBOOK PC/NB
CONTROLLED BY MASTER
1 |