APC Rack Systems manual Accessories COOLING, Rack Air Distribution Unit, Rack Air Removal Unit

Models: Rack Systems

1 20
Download 20 pages 14.51 Kb
Page 10
Image 10
Accessories: COOLING

Accessories: COOLING

Rack Air Distribution Unit

Air distribution for power dense enclosures and low pressure areas

The Rack Air Distribution Unit is a 2U fan unit that works with an existing precision air

conditioning system to deliver cool air to the equipment

contained in a rack enclosure. The Rack Air Distribution Unit connects into the raised floor and pulls supply air directly into the

enclosure. This prevents the conditioned air from mixing with warmer

room air before reaching the equipment. The Rack Air Distribution Unit minimizes temperature differences between the top and bottom of the enclosure. It also prevents hot exhaust air from recirculating to the inlet of the enclosure.

The product is recommended for rack enclosures with loads greater than 1.5kW and can provide airflow for loads up to 3.5kW. It is also ideal for enclosures in raised floor environments where underfloor air distribution is inadequate.

ACF001

(120VAC, 60HZ)

ACF002

(208/230VAC, 50/60HZ)

ACF003

(100VAC, 50/60HZ)

Rack Air Removal Unit

Performance heat removal for high density equipment in NetShelter® enclosures.

High density equipment creates an environment where traditional air distribution methods are often not effective. Densely packed enclosures can cause IT equipment to overheat, resulting in downtime. The Rack Air Removal Unit captures exhaust heat, ducting it to the return air plenum and eliminating hot spots. Through automatic fan speed adjustment based on temperature or power consumption, the fans will self-adjust for optimal performance.

With a unit-mounted LCD display users can view temperatures at the rack, monitor alarm conditions and adjust unit set points. The

integrated network management card allows for remote monitoring and control of the Rack Air Removal Unit. The Rack Air Removal Unit can cool up to a 16.5 kW rack and provide fan redundancy up to 12 kW, as well as

provide power redundancy through a dual corded input. This space-saving product mounts to the back of the NetShelter® enclosure—requiring zero U space.

ACF400

(100–240V 50/60HZ for NetShelter SX 600mm Wide Rack)

ACF402

(100–240V 50/60HZ for NetShelter SX 750mm Wide Rack)

ACF126

(ARU Ducting Kit for 24” Ceiling Tiles)

ACF127

(ARU Ducting Kit for 600mm Ceiling Tiles)

ACF122

(ARU Door Grille Kit)

Rack Side Air Distribution Unit

Air distribution for networking equipment with side-to-side airflow.

Housing equipment with side-to-side airflow creates many challenges for IT and facility managers, particularly in

regards to cooling. Because most enclosures are designed for a front to back airflow pattern, it is difficult

to maintain ideal operating temperatures on side-to-side

airflow equipment. The Rack Side Air Distribution Unit allows for greater security and organization by allowing racks to be placed adjacent to one another without impeding airflow.

The Rack Side Air Distribution Unit is a 2U rack mountable air distribution product for networking equipment or servers with side to side airflow. It pulls in conditioned air from the front of the rack and distributes it to the side air intake of the networking equipment. This extends equipment life by providing proper inlet temperatures.

This product is recommended for one or more networking products that are stacked consecutively in a rack. Rack Side Air Distribution Units may be placed above and/or below the networking equipment. Airflow pattern is user configurable via an interchangeable air turning vane.

ACF201BLK

(115VAC, 60HZ)

ACF202BLK

(208/230VAC, 50/60HZ)

fan trays

Roof Fan Tray (120, 208, 230 VAC) Black

ACF501(115 VAC, 600mm), ACF502 (208 – 230 VAC, 600mm), ACF503 (115 VAC, 750mm), and ACF504 (208  –  230 VAC, 750mm). (X-CertifieD)

Occupies 0U of rack space, Integrated cable access holes, promotes bottom to top airflow. Includes Installation Guide, mounting hardware.

Wall-Mount Fan Tray 120, 230 VAC Black

AR8206BLK (120 VAC), AR8207BLK (230 VAC)

Occupies 1U of rack space, promotes bottom to top airflow. Includes Installation Guide, Qty 1 – IEC to NEMA 5 –15P Power Cord (120V), IEC to IEC 320 Power (230V) Cord; Qty 2 – Fans.

Wall-Mount Ventilation Plate

AR8355

Ventilated. Includes Installation Guide.

To determine which cooling accessories are compatible with specific models of NetShelter® enclosures and racks, check the Accessory Compatibility Chart on page 16–17.

8

For more information about APC’s Availability Solutions, visit www.apc.com

Page 10
Image 10
APC Rack Systems Accessories COOLING, Rack Air Distribution Unit, Rack Air Removal Unit, Rack Side Air Distribution Unit