Function Button Quick-Reference
Function | Button | Timing | UPS | Description |
(seconds) | Status | |||
|
|
|
|
|
Power |
|
|
|
|
Power On
Power Off
0.2Off
2 On
Press POWER to start receiving input utility power. If A/C input power is not available, the unit will run on battery power.
The unit is not receiving input utility power, but is providing surge protection.
Display
Status Inquiry
Mute
0.2On
2 On
Verify the status or condition of the unit. The LCD will illuminate for 60 seconds.
The LCD will illuminate and the unit will beep to confirm the
Event Specific | 0.2 | On | Disable any audible alarms caused by an event. | |
General Status Enable/ | 2 | On | Enable or disable the audible alarms. The Mute icon will | |
Disable |
|
| illuminate and the unit will beep one time. The Mute function will | |
|
|
|
| not activate unless the UPS is operating on battery power. |
|
|
|
|
|
Sensitivity | 6 | Off | The Load Capacity icon will blink, indicating that the unit is in | |
|
|
|
| programming mode. Use the POWER button to scroll through |
|
|
|
| |
|
|
|
| Low, Medium, and High, stop at selected sensitivity. The unit will |
|
|
|
| beep to confirm selection. See Configuration for details. |
|
|
|
|
|
Master/Controlled | 2 | On | The leaf icon will darken indicating that the Master Outlet feature | |
outlet Enable/Disable |
|
| is disabled or illuminate to indicate the Master Outlet feature is | |
|
|
|
| enabled. The unit will beep once. |
|
|
|
|
|
Master/Enable | 6 | On | While calibrating the threshold setting, the device connected to | |
Threshold |
|
| the Master Outlet should be turned off or placed in Standby or | |
Calibration |
|
| Sleep mode. Upon completion, | |
|
|
|
| and beep 3 times. |
|
|
|
|
|
| 6 | On | The UPS will perform a test of the internal battery. Note: This | |
|
|
|
| will happen automatically when the unit is turned ON. |
|
|
|
|
|
Event Reset |
| 0.2 | On | When the Event screen is visible, press and hold DISPLAY, then |
|
|
|
| press POWER, to clear the utility failure event counter. |
|
|
|
|
|
Fault Reset | 2 | Fault | After a fault has been identified, press POWER to remove the | |
|
|
|
| visual indication and return to standby status. |
5 |