Rake continues to go through cleaning cycles.

Probable Cause:

Too much litter in the litter box is causing excess litter to collect behind the rake, preventing it from returning to home position or there is an obstacle in front at the rake. If the rake cannot move an obstacle during the cleaning cycle, the unit will go through a cleaning cycle up to five times in an attempt to clear the obstacle. If unsuccessful, the rake will return to its home position, and the green light will blink slowly (1 time per second), indicating that the rake has encountered an obstacle

it cannot move.

Solution:

1.Press the ON/OFF button to turn unit OFF.

2.Clear the obstacle.

Be sure litter in tray is just below the Full Line. Use the LitterMaid® triple- action tool to measure the level of the litter in the center of the unit. Full Line will not be visible if tray is overfilled.

3.Press the ON/OFF button ON.

4.The rake will run through a complete cleaning cycle. When cycle is finished, the unit is ready for use.

Unit does not operate 10 minutes after cat leaves.

Probable Cause:

• Dusty sensors (Sensors need to be covered for 5 seconds to activate.)

Solution:

1.Wipe each sensor with a soft, dry cloth.

2.Press the ON/OFF button to turn unit OFF.

3.Press the ON/OFF button ON.

4.Unit will run through a cleaning cycle.

Unit does not completely clean litter box.

Probable Cause:

Low-quality clumping litter.

Solution:

1.Do not use non-clumping, crystal or pearl-like litter.

2.Use only premium clumping litter.

Unit does not operate when you press ON/OFF button to turn unit ON.

Probable Cause:

Power outage

Faulty or non-activated outlet

Old batteries

Solution:

Check batteries and outlet

Use batteries in case of power outage

Switch to battery power

Probable Cause:

Incorrectly installed or dead batteries. (Batteries should only be used as backup.) Change the batteries once yearly.

Solution:

1.Press the ON/OFF button OFF.

2.Open battery compartment; check to see that batteries are correctly installed.

3.Press the ON/OFF button ON. The unit should perform a whole cleaning cycle.

4.If unit does not operate, replace batteries with fresh ones and try again.