Model 1610 Easy Install™ Media Air Cleaner Installation Instructions
WARNING
1.High voltage may cause serious injury from electrical shock. Disconnect power to the furnace/air handler before starting installation.
2.Sharp edges may cause injury from cuts. Use care when cutting and handling sheet metal.
CAUTION
1.To prevent component failure, do not install the air cleaner on the warm air supply or in an area where the temperature may exceed 140°F. This may include areas above heat exchangers in downflow furnaces or above exhaust flues in lowboy furnace cold air returns.
2.Installation must be done by a qualified heating and air conditioning professional. Read instructions thoroughly before beginning installation.
3.Do not install air cleaner downstream of a UV light. UV lamps will cause degradation of the filtering media.
SPECIFICATIONS
Airflow Capacity: up to 2000 CFM maximum
Replacement Media: Model 410 or 413 with SelfSeal™
Air Cleaner Operating Environment: Temperature: 0°F – 140°F
DIMENSIONS
Figure 1 – Air Cleaner Dimensions
28.2”
15.7”
30.1”
17.8” | 15.5” |
22.0”