MODEL 220-224

MAINTENANCE INSTRUCTIONS

for

APRILAIRE HUMIDIFIER MODELS 220-224

CAUTION! Sudden operation may cause personal injury or property damage. Turn humidistat to “off” or lowest setting before servicing.

 

5

 

1

1

6

 

2

2

 

4

3

3

1. “Z” Clip

2. Closure Clip

3. Closure Clip

4. Compression Fitting

5. Distribution Pan Cover

6. Feed Tube

1.Turn off water supply and turn down humidistat.

2.Remove three “Z” clips (1) that hold top half of unit to furnace plenum.

3.Slide off four closure clips (2 & 3) that hold two halves of unit together.

4.Loosen compression fitting (4) on copper feed tube (6) and remove.

5.Remove top screw holding sheet metal elbow to humidifier.

6.Remove top half of unit (lift straight up).

7.Remove the water distribution pan cover (5) and clean “V” openings in water distribution section but do not scrape off granular coating from bottom. This helps to insure proper, even water flow for maximum performance. See page 2 if removed.

8.Remove Water Panel evaporator and Scale Control Insert. Remove Water Panel evaporator from Insert and clean Insert by flexing or using putty knife. Inspect Water Panel evaporator and replace with a new Water Panel evaporator (Stock No. 10 for Model 220 and Stock No. 12 for Model 224), with colored spot up.

9.Remove the drain hose from the bottom of the unit and bend and flex it to loosen the internal calcium deposits. Then flush it with water under pressure and slip it back onto the black drain fitting.

10.IMPORTANT: When installing the Scale Control Insert and Water Panel evaporator in the humidifier, the Insert spout must discharge directly into unit drain.

11.Reassemble unit, position feed tube in compression fitting, tighten compression nuts and secure copper feed tube to upper housing with feed tube clamp. Attach to furnace plenum.

12.Turn on water supply, turn up humidistat and check unit operation.