Aprilaire specifications MODEL 500 SERIES HUMIDIFIER, Attention Installer, Specifications

Models: 50

1 2
Download 2 pages 63.9 Kb
Page 1
Image 1
ATTENTION INSTALLER:

READ COMPLETE SAFETY INSTRUCTIONS AND INSTALLATION TEMPLATE BEFORE STARTING INSTALLATION

ATTENTION INSTALLER:

This product must be installed by a qualified heating and air conditioning contractor. Failure to do so could result in serious injury from electrical shock.

This product must be installed in compliance with all local, state and federal codes.

Proper humidification and humidity control also requires that the home be constructed in accordance with local codes and good building practices.

 MODEL 500 SERIES HUMIDIFIER1.ELECTRICAL SHOCK HAZARD.RISK OF PROPERTY AND EQUIPMENT DAMAGE.SPECIFICATIONS2.SHARP EDGES HAZARD. Sharp3.RISK OF SCALDING. Water MODEL 500 SERIES HUMIDIFIER

RECOMMENDED WIRING DIAGRAMS WARNING

1.ELECTRICAL SHOCK HAZARD.

Model 500 CAUTION

RISK OF PROPERTY AND EQUIPMENT DAMAGE.

SPECIFICATIONS

HUMIDIFIER DIMENSIONS

Disconnect electrical power to the furnace before starting installation. Failure to do so could result in serious injury from electrical shock.

2.SHARP EDGES HAZARD. Sharp

edges may cause serious injury from cuts. Use care when making plenum openings and handling ductwork.

3.RISK OF SCALDING. Water

temperature over 125°F can cause severe burns and scald instantly. Shut off the hot water supply before disconnecting or tapping into any hot water supply line.

1.Do not install humidifier where freezing temperatures could occur. The water line could freeze and crack causing water damage to the home.

2.Do not install humidifier or bypass connection on the furnace jacket.

3.Do not install humidifier or bypass connection on a plenum face where the blanked off ends of the cooling coil will restrict air movement through the humidifier.

4.Do not set humidity level above recommended or to recommended level if condensation exists on inside windows of any unheated space, as condensation damage may result. Excess humidity can cause moisture accumulation which can allow the possibility for mold growth in the home.

5.Do not connect Model 500 or 500M transformer to blower motor wiring. Premature component failure may result.

6.When installing Humidifier Control on downflow furnace, ensure blower continues to run after a heat call is satisfiedto eliminate high temperatures from damaging the Humidifier Control.

7.Do not install humidifier where water pressure exceeds 125 psi, since damage to the humidifier may result. Follow codes in effect concerning pressure reduction.

8.Do not install humidifier on systems with greater than 0.4 in. wg pressure differential between supply and return plenums.

Width (including solenoid valve): 15 58

Height (including drain spud): 13”

Depth: 101 4

BYPASS DUCT OPENING

6” diameter

PLENUM OPENING

9 1 2”W x 9 1 2”H

WATER FEED RATE

3 gph

ELECTRICAL DATA

24 VAC-60 Hz, 0.5 AMP

RECOMMENDED WIRING DIAGRAMS

(SEE STEP 7 ON BACK AND “HUMIDIFIER CONTROL SAFETY AND INSTALLATION INSTRUCTIONS” FOR DETAILED WIRING INSTRUCTIONS)

Model 500

Model 500M

DIGITALHUMIDIFIER

 

 

 

 

 

 

 

 

 

 

MANUAL CONTROL

 

CONTROL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IMPORTANT

 

 

 

 

 

 

 

 

 

 

 

 

 

USE 120 VAC POWER SOURCE OTHER THAN FURNACE MOTOR

 

 

 

 

 

ADHC TERMINAL STRIP

 

 

 

 

CIRCUIT. HOWEVER, THE TRANSFORMER CAN BE POWERED

 

 

 

 

 

 

 

 

 

OFF THE HOT 120 VAC LINE BEFORE IT ENTERS THE FURNACE.

 

 

POWER

 

 

INPUTS

 

OUTPUTS

 

 

 

 

 

 

 

• DO NOT WIRE TRANSFORMER INTO FURNACE BLOWER CIRCUIT.

 

 

R

C

A

B

ODT

W

G

H

H

Gf

 

 

 

 

 

 

NORTH, EAST

 

 

 

 

 

 

 

 

 

 

 

24 VAC FURNACE

 

OR WEST SIDE

 

 

 

 

 

 

 

 

 

 

 

ACCESSORY TERMINALS

 

OF HOME

 

 

 

 

 

 

 

 

 

 

 

OR TRANSFORMER

 

 

 

 

 

 

 

 

 

 

 

 

 

(10VA MINIMUM)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHUT-OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

(SADDLE VALVE)

OUTDOOR

 

 

 

 

 

 

 

 

 

 

 

WATER SUPPLY

 

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

SENSOR FOR

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTOMATIC

 

 

 

 

 

 

 

 

 

 

 

 

 

MODE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMMON

YELLOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HI

24V SOLENOID

 

 

 

 

 

 

 

 

 

 

 

 

 

VALVE WIRES

ABOVE EXPECTED

 

 

 

 

 

 

 

 

 

 

 

LO

 

SNOW LINE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YELLOW

 

FURNACE

 

 

 

 

 

 

 

 

 

 

 

WIRES

 

 

 

 

 

 

 

 

 

 

 

 

 

BLOWER MOTOR

 

 

 

 

 

 

 

 

 

 

 

 

CONNECT DRAIN

 

 

 

 

 

 

 

 

 

 

 

CONNECT TO

 

 

 

 

 

 

 

 

 

 

 

 

LINE HERE

 

 

 

 

 

 

 

 

 

 

 

 

HOT WATER SUPPLY

 

 

 

R

R

 

 

 

 

 

 

 

 

 

 

MODEL 50

 

 

 

 

 

 

 

 

 

 

 

CURRENT

 

 

 

 

 

 

 

 

 

 

 

 

CONNECT DRAIN LINE HERE

 

C

 

 

 

 

 

 

 

 

 

 

SENSING RELAY

C

 

 

 

 

 

 

 

 

110 VAC

 

 

 

 

 

 

 

 

 

 

 

(IF REQUIRED)

 

 

 

 

 

 

 

 

 

 

 

 

G

G

 

 

 

 

 

 

 

 

 

 

IMPORTANT

 

 

 

 

 

 

 

 

 

 

 

 

WHEN MODEL 50 CURRENT SENSING RELAY IS USED:

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

Y

 

 

 

 

 

 

 

CONTINUOUSLY POWERED

 

• WIRE MODEL 50 CURRENT SENSING RELAY INTO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

W

 

 

 

 

 

 

 

 

24 VAC TRANSFORMER

 

24 VAC HUMIDIFIER CONTROL CIRCUIT ONLY!

 

 

 

 

 

 

 

 

 

PROVIDED WITH HUMIDIFIER

 

DO NOT INSTALL IN TRANSFORMER PRIMARY CIRCUIT.

 

 

 

 

 

 

 

 

 

 

 

 

THERMOSTAT

FURNACE

 

 

 

 

 

 

 

 

 

90-1510

 

90-1207

 

 

 

 

 

 

 

 

 

 

 

 

RESEARCH PRODUCTS CORPORATION • P.O. BOX 1467 • MADISON, WI 53701-1467 • CALL 800/334-6011 • FAX 608/257-4357

INSTALLATION OPTIONS

The Model 500 and 500M Aprilaire can be

installedon either the supply or return

plenum of a forced air handling system and is easily reversible for installation with right hand or left hand bypass duct connections. The humidifier dimensions and serviceabilitymust be considered when selecting the best location for the humidifier.Here are 2 examples of many types of installations.

Upflow

INSTALLATION OPTIONS SUPPLY

RETURN Upflow

Horizontal

RETURN

Horizontal SUPPLY

90-1079

NOTE

When installing the Aprilaire humidifier with the Aprilaire Digital Humidifier Control or on a heat pump system, use hot water. The heated water supplements the reduced supply air temperature as added heat for evaporation.

Page 1
Image 1
Aprilaire specifications MODEL 500 SERIES HUMIDIFIER, Attention Installer, Specifications, Recommended Wiring Diagrams