Aprilaire 600M specifications Recommended Wiring Diagrams, Installation Options, Specifications

Models: 600M

1 2
Download 2 pages 42.33 Kb
Page 1
Image 1
ATTENTION INSTALLER:

READ COMPLETE SAFETY INSTRUCTIONS AND INSTALLATION TEMPLATE BEFORE STARTING INSTALLATION

ATTENTION INSTALLER:

This product must be installed by a qualified heating and air conditioning contractor. Failure to do so could result in serious injury from electrical shock.

This product must be installed in compliance with all local, state and federal codes.

Proper humidification and humidity control also requires that the home be constructed in accordance with local codes and good building practices.

 MODEL 600 SERIES HUMIDIFIER1.ELECTRICAL SHOCK HAZARD.RISK OF PROPERTY AND EQUIPMENT DAMAGE.SPECIFICATIONS2.SHARP EDGES HAZARD. Sharp3.RISK OF SCALDING. Water MODEL 600 SERIES HUMIDIFIER

RECOMMENDED WIRING DIAGRAMS WARNING

1.ELECTRICAL SHOCK HAZARD.

Model 600 CAUTION

RISK OF PROPERTY AND EQUIPMENT DAMAGE.

SPECIFICATIONS

HUMIDIFIER DIMENSIONS

Disconnect electrical power to the furnace before starting installation. Failure to do so could result in serious injury from electrical shock.

2.SHARP EDGES HAZARD. Sharp

edges may cause serious injury from cuts. Use care when making plenum openings and handling ductwork.

3.RISK OF SCALDING. Water

temperature over 125°F can cause severe burns and scald instantly. Shut off the hot water supply before disconnecting or tapping into any hot water supply line.

1.Do not install humidifier where freezing temperatures could occur. The water line could freeze and crack causing water damage to the home.

2.Do not install humidifier or bypass connection on the furnace jacket.

3.Do not install humidifier or bypass connection on a plenum face where the blanked off ends of the cooling coil will restrict air movement through the humidifier.

4.Do not set humidity level above recommended or to recommended level if condensation exists on inside windows of any unheated space, as condensation damage may result. Excess humidity can cause moisture accumulation which can allow the possibility for mold growth in the home.

5.Do not connect Model 600 or 600M transformer to blower motor wiring. Premature component failure may result.

6.When installing Humidifier Control on downflow furnace, ensure blower continues to run after a heat call is satisfied to eliminate high temperatures from damaging the Control.

7.Do not install humidifier where water pressure exceeds 125 psi, since damage to the humidifier may result. Follow codes in effect concerning pressure reduction.

8.Do not install humidifier on systems with greater than 0.4 in. wg pressure differential between supply and return plenums.

Width (including solenoid valve): 15 38” Height (including drain spud): 15 34” Depth: 101 4

BYPASS DUCT OPENING

6” diameter

PLENUM OPENING

10”W x 12 34”H

WATER FEED RATE

3 gph

ELECTRICAL DATA

24 VAC-60 Hz, 0.5 AMP

RECOMMENDED WIRING DIAGRAMS

(SEE STEP 7 ON BACK AND “HUMIDIFIER CONTROL SAFETY AND INSTALLATION INSTRUCTIONS” FOR DETAILED WIRING INSTRUCTIONS)

Model 600

DIGITAL HUMIDIFIER CONTROL

INSTALLATION

OPTIONS

The Model600 and 600M Aprilairecan be installed on eitherthe supplyor returnplenumof a forced air handlingsystemand is easilyreversiblefor installationwith righthand or left hand bypassduct

NORTH, EAST

OR WEST SIDE

OF HOME

OUTDOOR TEMPERATURE

SENSOR FOR

AUTOMATIC MODE

ADHC TERMINAL STRIP

 

POWER

 

 

 

INPUTS

 

OUTPUTS

 

 

R C

 

A B

 

ODT W G

 

H H Gf

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connections.The humidifierdimensionsand serviceabilitymust be consideredwhen selecting the best locationfor the humidifier.Here are

2 examplesof many typesof installations.

Upflow

INSTALLATION SUPPLY

ABOVE EXPECTED

SNOW LINE

90-1510

R

C

G

Y

W

THERMOSTAT

R

C

G

Y

WUpflow

FURNACE

YELLOW WIRES Model 600M

110 VAC

 

 

CONNECT DRAIN

 

 

CONNECT TO

 

LINE HERE

 

 

HOT WATER SUPPLY

 

CONTINUOUSLY POWERED

24 VAC TRANSFORMER

PROVIDED WITH HUMIDIFIER

RETURN Horizontal

Model 600M

MANUAL CONTROL

IMPORTANT

USE 120 VAC POWER SOURCE OTHER THAN FURNACE MOTOR

CIRCUIT. HOWEVER, THE TRANSFORMER CAN BE POWERED

OFF THE HOT 120 VAC LINE BEFORE IT ENTERS THE FURNACE.

• DO NOT WIRE TRANSFORMER INTO FURNACE BLOWER CIRCUIT.

24 VAC FURNACE ACCESSORY

 

TERMINALS OR TRANSFORMER

 

 

(10VA MINIMUM)

SHUT-OFF

 

 

(SADDLE VALVE)

 

 

WATER SUPPLY

COMMON

 

 

HI

MODEL 50

 

CURRENT SENSING RELAY

YELLOW 24V

 

 

(IF REQUIRED)

LO

SOLENOID

 

 

IMPORTANT

VALVE WIRES

 

 

WHEN MODEL 50 CURRENT

FURNACESENSING RELAY IS USED:

BLOWER MOTOR

• WIRE MODEL 50 CURRENT

 

SENSING RELAY INTO 24 VAC

 

HUMIDIFIER CONTROL

 

CIRCUIT ONLY! DO NOT

90-1207

INSTALL IN TRANSFORMER

 

PRIMARY CIRCUIT.

 

Manual background CONNECT DRAIN LINE HERE

Horizontal

RETURN

Manual background SUPPLY

90-1079

NOTE

When installingthe Aprilairehumidifierwith the AprilaireDigital HumidifierControl or on a heat pump system, use hot water.The heated water supplementsthe reduced supply air temperatureas added heat for evaporation.

RESEARCH PRODUCTS CORPORATION • P.O. BOX 1467 • MADISON, WI 53701-1467 • CALL 800/334-6011 • FAX 608/257-4357

Page 1
Image 1
Aprilaire 600M specifications Recommended Wiring Diagrams, Installation Options, MODEL 600 SERIES HUMIDIFIER, Model