Set time and day

Operation & Programming

Set time and day

1..Press Understanding program schedules to enter time setting mode.. Hour and AM/PM are flashing..

2..Press Understanding program schedules (continued) or Set temps to adjust the hour..

3..Press Start time, the minutes flash.. Press Progressive recovery or

Example: to adjust the minutes..

4..Press Manual background, the day flashes.. Press Manual background or

Manual background to adjust day..

5..Press Manual background to end. “DONE” will display.

The thermostat will return to normal mode if no key is pressed within 3 seconds..

Understanding program schedules

The daily schedule is split into four sections:

WAKE: 6am-8am – Temperature you would prefer to wake up to, until you leave for the day.

LEAVE: 8am-5pm – Temperature when you are away from the house during the day..

RETURN: 5pm-10pm – Temperature you would prefer to return to, until bedtime.

SLEEP: 10pm-6am – Temperature you would prefer during the night..

The times shown are the defaults.. The start time and temperature of each section can be changed to fit your schedule (see page 10)..

Operation & Programming

Understanding program schedules (continued)

 

 

 

 

Set temps

Event

Event designator

Start time

Heat

 

Cool

 

 

 

 

 

 

1

WAKE

6:00AM

70°F (21°C)

 

78°F (26°C)

 

 

 

 

 

 

2

LEAVE

8:00AM

62°F (17°C)

 

85°F (29°C)

 

 

 

 

 

 

3

RETURN

5:00PM

70°F (21°C)

 

78°F (26°C)

 

 

 

 

 

 

4

SLEEP

10:00PM

62°F (17°C)

 

82°F (28°C)

 

 

 

 

 

 

Progressive recovery

The Progressive Recovery feature allows the thermostat

Example:

to activate the heating and cooling equipment prior to

Set the Wake time to 6 am, and the temperature to 70°.

an event in order to reach the desired temperature at

The heat will come on before 6 am, so the temperature

the start of the next scheduled event..

is 70° by the time you wake at 6.