Setup & Testing
System test menu
The system test menu is used to test a system after installation.. The outputs of the thermostat can be manually activated to test their function. The instructions below show how to enter the test mode and turn outputs on and off.
How to enter the system test menu:
Press [MODE] to set system to off..
Press and hold [FAN] and [MODE] for three seconds to enter system test mode..
The screen of the first test step #60 is displayed:
TEST NUMBER | MODEL | FLASHES | |
| (SW1 SETTING) | IF 24VAC | |
|
|
| IS NOT |
|
|
| PRESENT |
OUTPUT |
|
|
|
|
|
| |
STATE |
|
|
|
The test number is displayed on the upper left, and the output state is displayed in the message center..
Press to turn on the output (01).. For multi stage output, press
again to turn on the 2nd stage (02)..
Press to turn off all the output (00)..
Press [BACK] or [NEXT] to change to the next test step..
When the last step (63) is done, press [NEXT].. The message “installer test complete“ will display..
All minimum on and off timers will be reset after returning from system test mode..
Note: Second stage will only be displayed when the thermostat is set to
STAGE
Test Number
System test
60Heating equipment test
61Cooling equipment test
62Auxiliary equipment test (HP only)
63Fan equipment test
8
61000729A 8600 Tstat Install.indd 8 | 10/8/10 10:32:43 AM |