INSTALLER SYSTEM SETTINGS TABLE (continued)

 

 

Factory default setting (bold)

System setting

Description

and setting range

 

 

 

19. THIRD STAGE

3rd stage differential..

1°F (0.5°C)

DIFFERENTIAL

 

1°F to 9°F (0.5°C to 4.5°C)

20. FOURTH STAGE

4th stage differential..

1°F (0.5°C)

DIFFERENTIAL

 

1°F to 9°F (0.5°C to 4.5°C)

21. INTEGRAL FACTOR

Short period = more cycles per hour (comfort)

2 MINUTES

PERIOD

Long period = less cycles per hour (economical).

1 to 5 minutes or “OFF” for proportional

 

 

control only

22. LOW BALANCE POINT

Outdoor temperature low balance point

20°F (–6°C)

 

(This option is only displayed if the outdoor

10°F to 50°F (-12°C to 9°C) or OFF to ignore

 

temperature sensor is enabled)..

 

23. HIGH BALANCE POINT

Outdoor temperature high balance point

65°F (18°C)

 

(This option is only displayed if the outdoor

40°F to 85°F (3°C to 30°C) or OFF to ignore

 

temperature sensor is enabled)..

 

24. EXTENDED FAN – HEAT

Extends fan operation after heat call ends.

DISABLE

 

 

ENABLE (90 second extension)

25. EXTENDED FAN – COOL

Extends fan operation after cool call ends.

DISABLE

 

 

ENABLE (90 second extension)

26. PROGRESSIVE

Enable or disable Progressive recovery.

DISABLE

RECOVERY

 

ENABLE

27. DEADBAND

Auto changeover mode dead band.

3°F (2°C)

 

 

2°F to 9°F (1°C to 5°C)

28. HUMIDISTAT MODE

Sets humidity control mode..

HUMIDIFY

 

 

DEHUMIDIFY

 

 

AUTO

 

 

OFF

29. TEMPERATURE SCALE

Set the thermostat to Fahrenheit or Celsius

FAHRENHEIT

 

mode..

CELSIUS

30. AUTO DAYLIGHT

Enable or disable auto daylight savings.

OFF

SAVINGS

 

MARCH (second Sunday in March to the

 

 

first Sunday in November)

 

 

APRIL (first Sunday in April to the last Sunday

 

 

in October)

32. CONSTANT BACKLIGHT

Enable constant, low intensity, backlight when

DISABLE

 

24VAC is present.

ENABLE

33. BACKLIGHT INTENSITY

Backlight intensity as a percentage of full on.

100 PERCENT

 

 

0 – 100%

34. SENSOR OFFSET

Field adjustment of the controlling temperature

0°: No offset applied

 

sensor..

–8°F to +8°F (-4°C to +4°C)

35. PROGRAM FORMAT

Select weekly program format..

7-DAY (Mon, Tue, Wed, Thu, Fri, Sat, Sun)

 

 

5/1/1 (weekdays, Saturday and Sunday)

 

 

5/2 WEEKDAYS (weekdays and weekends)

 

 

NON-PROG

36. EVENT CONFIGURATION

Setting for event naming.

RESIDENTIAL

 

 

COMMERCIAL

37. EVENTS PER DAY

Number of program events per day.

FOUR

 

 

TWO

38. USER SECURITY SETUP

Enable or disable security setup system

DISABLE

 

variables in the User Setup Screens.

ENABLE

39. SECURITY

Enable or disable security..

DISABLE

 

 

ENABLE

40. SECURITY PIN

Security pin code..

####

 

 

4-digit numeric pin

Setup & Testing

INSTALLER SYSTEM SETTINGS TABLE (continued)

 

 

Factory default setting (bold)

System setting

Description

and setting range

 

 

 

41. LOCKOUT TYPE

Screen lockout level. (Override lockout by

OFF

 

holding [MENU] for 7 seconds).

PARTIAL

 

 

FULL

42. MODE LOCKOUT

System mode lockout setting..

DISABLE

 

 

ENABLE

43. FAN LOCKOUT

Fan Mode lockout setting..

OFF

 

 

TIMED

 

 

FULL

44. SETPOINT LOCKOUT

Setpoint lockout setting..

OFF

TYPE

 

TIME-LIMITED

 

 

RANGE-LIMITED

 

 

TIME AND RANGE

 

 

FULL

45. MAX SETPOINT

Select setpoint limits (only available when

+/-5 DEGREES (from current setpoint)

CHANGE IN LOCKOUT

lockout is set to partial lockout)..

±1° to 20° OFF indicates no setpoint changes

 

 

or

 

 

+/-5% RH (from current setpoint)

 

 

±1% to 20% OFF indicates no setpoint changes

46.TEMPORARY CHANGE Time-limited lockout temporary change period.. 60 MINUTES

PERIOD

 

Selection of 0 to 255 minutes in 5 minute step;

 

 

0 indicates no temporary change period.

47. NETWORK OVERRIDE

Network override feature setting.

ENABLE

 

 

DISABLE

48. DISPLAY REMOTE

Enable or disable display of support module

ENABLE

SENSORS

monitor (remote) sensor readings..

DISABLE

49. AIR FILTER ALARM

The period for displaying the “Change Air

OFF

PERIOD

Filter” message.

1, 3, 6, 12 MONTHS or “OFF” to disable

50. WATER PANEL ALARM

Set number of months until the first reminder

OFF

PERIOD

is required.. The following reminders will occur

1 to 12 MONTHS or “OFF” to disable

 

every 12 months for a flow through humidifier,

 

 

and 3/9 months for a drainless humidifier.

 

51. HUMIDIFIER TYPE

Select humidifier type.. Flow through type

FLOW THROUGH (1 reminder per season)

 

gives a 12 month reminder, and drainless

DRAINLESS (2 reminders per season)

 

gives a 3/9 month reminder.

 

52. DEHUMIDIFIER ALARM

The period for displaying the “Service

OFF

PERIOD

Dehumidifier” message.

1 to 12 MONTHS or “OFF” to disable

53. HVAC ALARM PERIOD

The period for displaying the “Service HVAC”

OFF

 

message..

1 to 12 MONTHS or “OFF” to disable

10

11

Page 6
Image 6
Aprilaire 8800 installation instructions Installer System Settings Table, Factory default setting bold

8800 specifications

The Aprilaire 8800 series is an advanced, high-performance air management system designed for residential use, providing homeowners with superior indoor air quality (IAQ) and comfort. This innovative model stands out for its combination of reliable filtration, user-friendly operation, and cutting-edge technology aimed at ensuring a healthier living environment.

One of the main features of the Aprilaire 8800 is its advanced filtration system. Equipped with a high-efficiency particulate air (HEPA) filter, the device is capable of capturing 99.97% of airborne particles as small as 0.3 microns. This includes dust, pollen, pet dander, and even smoke, making it an essential addition for allergy sufferers or those in areas with high pollution levels. The filter has a long lifespan, generally lasting up to a year, which reduces the hassle of frequent replacements and maintenance.

The Aprilaire 8800 is also designed to control humidity levels effectively. Maintaining optimal humidity levels is crucial for comfort and health, as excessive moisture can lead to mold growth and dust mites, while too little humidity can cause dry skin and respiratory issues. This product includes a built-in humidistat that helps monitor and adjust the humidity levels accordingly.

In terms of operation, the Aprilaire 8800 features an intuitive digital control interface. Homeowners can easily set their desired temperature and humidity levels, while the system automates adjustments to maintain these settings. Additionally, the unit is designed for quiet operation, ensuring that it does not intrude on the comfort of daily life.

The technology utilized in the Aprilaire 8800 series contributes to its efficiency and effectiveness. It is designed for compatibility with most HVAC systems, making it a versatile choice for varying home environments. The system also includes multiple fan speed settings to increase air circulation without compromising energy efficiency.

Overall, the Aprilaire 8800 is an excellent choice for those seeking enhanced air quality and comfort in their homes. With its robust filtration capabilities, humidity control features, and user-friendly interface, it stands out as a reliable option for improving indoor air quality. By investing in an Aprilaire 8800, homeowners can enjoy cleaner, healthier air while also protecting their living spaces from the adverse effects of poor air quality.