PROGRAMMING AND OPERATION
Total Control Menus (System configuration must indicate Total Control configuration and is automatically detected when the electrical connections are made between the #75003 and #75001 systems)
Set pH overfeed (Range: No pH overfeed - 120 minutes in 5 minute increments) (Used to stop the chlorine and acid feed if the pH set point is not reached in the user programmed time.)
1.Press MENU, press ∆ or ∇ until “Maintenance menu” is displayed, then press SELECT.
2.Press ∆ or ∇ until “pH overfeed” is displayed, then press SELECT (No pH overfeed is the factory setting).
3.Press ∆ or ∇ to the desired overfeed time setting, then press SELECT.
4.Press ∆ or ∇ until “End menu mode” is displayed, then press SELECT.
Set pH min (Used to set the lower limit of pH adjustment before a warning message is displayed)
1.Press MENU, press ∆ or ∇ until “Maintenance menu” is displayed, then press SELECT.
2.Press ∆ or ∇ until “Set pH min” is displayed, then press SELECT (6.5 is the factory setting).
3.Press ∆ or ∇ to the desired pH min setting, then press SELECT.
4.Press ∆ or ∇ until “End menu mode” is displayed, then press SELECT.
Set pH max (Used to set the upper limit of pH adjustment before a warning message is displayed)
Note: For safety reasons, acid will not feed when measured above the programmed pH max.
1.Press MENU, press ∆ or ∇ until “Maintenance menu” is displayed, then press SELECT.
2.Press ∆ or ∇ until “Set pH max” is displayed, then press SELECT (8.0 is the factory setting).
3.Press ∆ or ∇ to the desired pH max setting, then press SELECT.
4.Press ∆ or ∇ until “End menu mode” is displayed, then press SELECT.
Calibrate pH (Used to match the pH display of the Digital to the results of a reliable pH test kit)
1.Press MENU, press ∆ or ∇ until “Maintenance menu” is displayed, then press SELECT.
2.Press ∆ or ∇ until “Calibrate pH” is displayed, then press SELECT (the pH sensor measurement will be displayed).
3.Press ∆ or ∇ to match a reliable pH test result, then press SELECT.
4.Press ∆ or ∇ until “End menu mode” is displayed, then press SELECT.
Enable / Disable ORP (Used to temporarily enable or disable the ORP control system, thus disabling the chlorine generation)
1.Press MENU, press ∆ or ∇ until “Maintenance menu” is displayed, then press SELECT.
2.Press ∆ or ∇ until “Enable ORP or Disable ORP” is displayed, then press SELECT.
•if “Enable ORP” then the ORP sensor is disabled, press SELECT to enable the ORP sensor.
•if “Disable ORP” then the ORP sensor is enabled, press SELECT to disable the ORP sensor.
3.Press ∆ or ∇ until “End menu mode” is displayed, then press SELECT.
Set ORP overfeed (Range: No ORP overfeed - 120 minutes in 5 minute increments) (Used to stop the chlorine and acid feed if the ORP set point is not reached in the user programmed time.)
1.Press MENU, press ∆ or ∇ until “Maintenance menu” is displayed, then press SELECT.
2.Press ∆ or ∇ until “ORP overfeed” is displayed, then press SELECT (No ORP overfeed is the factory setting).
3.Press ∆ or ∇ to the desired overfeed time setting, then press SELECT.
4.Press ∆ or ∇ until “End menu mode” is displayed, then press SELECT.
36