TROUBLESHOOTING GUIDE
Total Control Error Displays
Message on Display | Problem | Typical Solution |
|
|
|
Error! Purifier off | Flow at sensors is not detected. Chlorine and acid | Ensure sufficient flow to the flow cell, pg. 44. |
Error! Acid off | are not fed under these conditions, until corrected. | Open the inlet and outlet valves to the flow cell. |
Check flow at sensors |
| Valve handles should be vertical. |
|
| Verify that the sample water valve is closed, |
|
| valve handle horizontal. |
Error! Purifier off | The measured ORP is out of range and may be | Check and secure ORP connections. |
Error! Acid off | caused when the sensor is not properly connected | Replace ORP sensor. |
Check ORP sensor | or if the sensor is past its useful life. Out of range |
|
| ORP measurement is below 100 mv or above 900 |
|
| mv. Chlorine and acid are not fed under these |
|
| conditions, until corrected. |
|
Error! Purifier off | The measured ORP has not reached its set point | Clear the ORP overfeed warning by |
Error! Acid off | within a user programmable time, between No | programming ORP overfeed OFF and back ON, |
ORP overfeed | ORP Overfeed to 120 minutes. The factory setting | pg. 36. |
| is “No ORP overfeed”. Chlorine and acid are not | Check the operation of the purifier mode by |
| fed under these conditions, until corrected. | ensuring proper salt, pH, and stabilizer levels. |
|
| Check and clean ORP sensor. |
|
| Check “Other conditions” on pg. 47. |
Error! Purifier off Error! Acid off Check pH sensor
The measured pH is out of range and may be caused when the sensor is not properly connected or if the sensor is past its useful life. Out of range pH measurement is below 4.0 or above 9.9. Chlorine and acid are not fed under these conditions, until corrected.
49