TROUBLESHOOTING GUIDE
Troubleshooting Guide
Visit www.AutoPilot.com for the latest manual revisions, additional information and helpful troubleshooting tips. You can also reach our factory direct customer assistance by calling 800.922.6246 or 954.772.2255, by email at AutoPilotTechSupport@teamhorner.com, or by FAX at 954.772.4070.
Run the “View Setup” (pg. 31) and record the information displayed and have the information available prior to contacting AutoPilot.
•Current measured salt level
•Software version
The following will also be needed but may have been recorded by the installer in the front of your manual on pg. iii.
•Date of installation
•Control Unit model type should be # 75003
•Control Unit serial number
•SuperCell model type
•SuperCell serial number
•
Message on Display | Problem | Typical Solution | ||
Error! Purifier off | Chlorine generation has | 1. | Turn the circulation pump on. | |
Error! Acid off | stopped due to | 2. | Turn the control valves to the correct position to allow water flow | |
Check Flow | insufficient water flow. |
| through the manifold. | |
|
| 3. | If a suction type vacuum cleaner is used, then clean if clogged. | |
|
| 4. | Check and clean the skimmer basket. | |
|
| 5. | Check and clean the pump basket. | |
|
| 6. | Check and clean or backwash the main circulation filter. | |
|
| 7. | Clean the manifold screen of trash or debris. Testing the Flow Switch, | |
|
|
| Cleaning the Filter Screen, and Cleaning the Bypass Valve (see pg 41) | |
|
| 8. | Verify that the | |
|
|
| orient it correctly before inserting it. (Warning: Read warning, | |
|
|
| instructions and see illustrations in Connecting the | |
|
|
| Cable on pg. 15) | |
|
| 9. | Clean the SuperCell if plugged with debris or calcium scale? (See the | |
|
|
| sections under SuperCell on pgs. 41 - 42 for directions on removing, | |
|
|
| inspecting, and cleaning). | |
|
| 10. | Check for air in the manifold by loosening the top union on the cell to | |
|
|
| see if air or water comes out. If air comes out then there may be a | |
|
|
| vacuum side leak or the pump may be undersized. Check for leak at | |
|
|
| pump basket | |
|
| 11. | If the pump is a | |
|
|
| may not create enough flow for the manifold. | |
Purifier OFF! | Chlorine generation has | Add salt as indicated on the Digital display to bring the salt level up to | ||
Add Salt xxx lbs | stopped because the salt | 3000 ppm (3.0 g/l). | ||
| level is below 1900 |
|
| |
| ppm, which is too low. |
|
| |
Warning! | The salt level is | Add salt as indicated on the Digital display to bring the salt level up to | ||
Add Salt xxx lbs | between | 3000 ppm (3.0 g/l). | ||
| ppm, which is low. |
|
| |
Purifier OFF! | Added salt as indicated | 1. | The pool volume has not been set up in the Installer Menu and is | |
Add Salt xxx lbs or | by the Pool Pilot, but |
| higher than the factory default of 15,000 gallons (56,000 liters). | |
Warning! | salt level still shows | 2. | The salt sensor in the | |
Add Salt xxx lbs | low. | 3. | The Salt display may need to be calibrated. | |
| Salt level on display | 1. | The test may have been faulty or the salt strips may be old or | |
No Error Displays | does not match pool |
| damaged. Have your salt level | |
store or salt test strip. | 2. | If the discrepancy is more than 400 ppm (4 mg/l), then contact | ||
| ||||
|
|
| AutoPilot Systems. If the | |
|
|
| salt sensor may need to be |