8
OPERATING INSTRUCTIONS
Before proceeding with the operation of the heater make
sure that the system is filled with water.
Make sure the water heater drain plug is closed. See Figure
7 below.
Fig. 7 - Water heater drain plug
Open the cold water inlet supply to the heater fully.
Open a hot water faucet to permit the water to fill the heater
and the piping and to eliminate the air trapped in the system
Close the hot water faucet after the water flows freely and
all the air has escaped from the system. The water heater
is now ready to work
FOR YOUR SAFETY READ BEFORELIGHTING THE PILOT
Warning: If you do not follow these instructions exactly, a
fire or explosion may result causing property damage,
personal injury or loss of life
A. This appliance has a piezo-igniter for lighting the pilot
burner. When lighting the pilot, follow these instructions
exactly.
B. BEFORE LIGHTING smell all around the appliance
area for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electric switch; do not use any phone
in your building
- Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
- If you cannot reach your gas supplier, call the fire
department.
C. Use only your hand to push in or turn the gas control
buttons. Never use tools. If a button will not push in, check
to make sure the buttons are being pushed in the proper
sequence. Follow these instructions exactly. If control
button(s) are jammed, close the gas supply and call a
qualified service technician. Attempted forceful repair may
result in a fire or explosion.
D. Do not use this appliance if any part has been under
water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the control
system and any gas control which has been under water.