30
CONTINUITY DIAGRAM

Model 926500, 501

PS0841
The diagrams below show the various states of connection for electrical components.
The solid lines on switchs show continuity.
NOTE: All switches are viewed from the rear.
S
A
M
BR
GS
A
M
BR
GS
A
M
BR
G
OFF RUN START HAND WARMER
OFF HAND WARMER
ON
NOT ENERGIZED ENERGIZED
Key Switch
(02739600) Hand Warmer Switch
(02485700)
Solenoid (Top View)
(03679000)