Connecting the drain hose
! CAUTION: if this appliance is supplied from a | EN | |
cord extension set or electrical portable outlet | ||
|
65 - 100 cm |
Connect the drain hose to drain duct piping or a wall drain located between 65 and 100 cm above the floor, making sure it is not bent at all.
device, the cord extension set or electrical |
portable outlet device |
must be positioned so that it is not subject to |
splashing or ingress of moisture. |
! The cable should not be bent or |
compressed. |
! The cable should be replaced only by |
authorised technicians. |
! If the supply cord is damaged, it must be |
replaced by the manufacturer, its service agent |
Alternatively, rest the drain hose on the side of a washbasin or bathtub, fastening the duct supplied to the tap (see figure). The free end of the hose should not be underwater.
!We advise against the use of hose extensions; if it is absolutely necessary, the extension must have the same diameter as the original hose and must not exceed 150 cm in length.
Electrical connections
Before inserting the plug into the electrical socket, make sure that:
•the socket is earthed and complies with current regulations;
•the socket can withstand the maximum load of the appliance, which is indicated in the Technical data table (see opposite);
•the power supply voltage falls within the values indicated in the Technical data table (see opposite);
•the socket is compatible with the plug of the appliance. If this is not the case, either the socket or the plug must be replaced.
!The machine must not be installed outdoors, even in covered areas. It is extremely dangerous to leave the appliance exposed to rain, storms and other weather conditions.
!Once the machine has been installed, the electricity socket should be easily accessible.
!Avoid using any extension cord or multiple socket outlet.
or similarly qualified persons in order to avoid a |
hazard. |
Warning! The company shall not be held responsible in the event that these regulations are not respected.
Technical data
Model | ADS9D 297 |
| |
| width 59.5 cm |
| |
Dimensions | height 85 cm |
| |
| depth 64,5 cm |
| |
Capacity | from 1 to 9 kg |
| |
|
| ||
Electrical | please refer to the technical | ||
data plate fixed to the ma- | |||
connections | |||
chine |
| ||
|
|
| |
| maximum pressure |
| |
Water con- | 1 MPa (10 bar) |
| |
minimum pressure |
| ||
nections |
| ||
0.05 MPa (0.5 bar) |
| ||
|
| ||
| drum capacity 62 litres | ||
|
| ||
Spin speed | up to 1200 rotations per | ||
minute |
| ||
|
| ||
Energy ra- |
|
| |
ted | Program Cotton | ; tem- | |
programmes | |||
according to | perature 60°C; 1200 rpm, | ||
AS/NZS | using a load of 9 kg. |
| |
2040.2 |
|
|
This appliance conforms to the following EC Directives: - 2004/108/EC (Electroma- gnetic Compatibility)
-2006/95/EC (Low Voltage)
-2002/96/EC
3