INSTALLATION & DUCTING

TOP DUCTING

SIDE DUCTING

RE-CIRCULATING

 

 

(Carbon filter required)

DUCTED OPTION

NOTICE // ALL DUCTING MATERIAL MUST BE COMPLIANT WITH THE LOCAL LAWS IN FORCE.

INSTALLATION

1.Remove the filter and light globes. (If installed)

2.Remove the stainless steel fascia (4 screws) – take care not to damage the fascia.

3.Determine the most efficient path for the ductwork, minimise bends and keep the length of the ductwork to a minimum.

4.It is important to run and finish (install roof / wall caps) prior to installation of the hood.

5.Cut out the cabinetry as per the installation diagram. Ensure that access has been allowed for the power cable.

6.Hold the hood up to the underside of the cabinet (2 people required); Screw the hood to the cabinetry.

7.Attach the ducting adaptor to the ducting.

8.Re-install the stainless steel fascia.

9.Re-install filter.

10.Plug in the power to the unit, turn on and test.

WARNING // Do not penetrate any screws into the rangehood as this may result in electrical hazards. Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards.

 

 

pg 6

www.aristonbrand.com

Page 6
Image 6
Ariston ARU75X, ARU52X user manual Ducted Option Installation