Pay particular attention to the plug wires and thermocouple tubes.

Pay particular attention to the plug wires and thermocouple tubes.

Important

On completion of the operation, replace the old rating sticker with one indicating the new type of gas used. This sticker is available from our Service Centres.

Note

Should the pressure of the gas used be different (or vary) from the recommended pressure, it is necessary to fit a suitable pressure regulator onto the inlet pipe in compliance with current National Regulations relative to “regulators for channelled gas”.

Burner and nozzle characteristics

Table 1

 

 

 

 

 

Liquid Gas

 

 

 

Natural Gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Burner

Diameter

Thermal Power

By-Pass

Nozzle

 

Flow*

 

Nozzle

 

Flow*

 

(mm)

kW (p.c.s.*)

1/100

1/100

 

g/h

 

1/100

 

l/h

 

 

Nominal

 

Reduced

(mm)

(mm)

***

 

 

**

(mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fast

100

3.00

 

0.7

41

87

218

 

 

214

128

 

286

(Large)(R)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Semi Fast

75

1.90

 

0.4

30

70

138

 

 

136

104

 

181

(Medium)(S)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

51

1.00

 

0.4

30

52

73

 

 

71

76

 

95

(Small)(A)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Oven

-

3.10

 

1.0

46

85

225

 

 

221

132

 

295

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Grill

-

2.50

 

-

-

80

182

 

 

179

122

 

227

 

 

 

 

 

 

 

 

 

 

 

 

 

Supply

Nominal (mbar)

 

 

28-30

 

37

 

20

Minimum (mbar)

 

 

20

 

 

25

 

17

Pressures

 

 

 

 

 

Maximum (mbar)

 

 

35

 

 

45

 

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*At 15°C and 1013 mbar- dry gas

**

Propane

P.C.S. = 50,37 MJ/Kg

***

Butane

P.C.S. = 49,47 MJ/Kg

 

Natural

P.C.S. = 37,78 MJ/m3

S S

A R

K3G2/G

K3G21/G

7

Page 7
Image 7