OPERATING INSTRUCTIONS
Electronic Ballast ARRI EB 575 EVENT SIX
1.General Remarks Please read the following operating instructions very carefully before using the Electronic Ballast (EB) the first time. They contain important information and instructions for the safety, use and maintenance of the appliance. For your own safety please follow all safety instructions and warnings.
Keep the operating instructions carefully in a safe place and pass them to any future owner.
2.Important Safety 2.1 Warning - High voltages inside ballast! Danger to life!
Instructions | Disconnect EB from power supply before opening (pull out the line plug). Do not pull |
| on the connection cable, but on the plug, to disconnect the EB from mains. Any repairs |
| or changing of the line plug must only be carried out by qualified personnel or ARRI- |
| service departments. |
| 2.2 Before connecting the Electronic Ballast ensure that the power supply is correctly |
| wired. Do not use without adequate earth connection unless either an isolation |
| transformer or an |
| Note: In order to avoid unwanted tripping due to leaking currents and transient |
| disturbances, care shall be taken that the collective leakage current of equipment on the |
| load side of a residual current device is less than 1/3 of its rated residual current. |
| The typical leakage current of this device is max 1mA (according EN |
| appendix G). |
| 2.3 Lamphead must be disconnected from Electronic Ballast and Electronic Ballast |
| must be disconnected from mains before fitting or replacing a lamp. |
| 2.4 The Electronic Ballast must be switched off before connecting or disconnecting |
| either head or supply cable. Do not use other than original ARRI cables and connectors |
| with permitted cross section of the leads. The ballast is only suitable for specified ARRI |
| luminaires (see fig. 1, page 15). Using other than original ARRI cables or luminaires |
| may cause injury to the user as well and/or damage to the ballast. |
| 2.5 The Electronic Ballast satisfies the standards of the recognized state of the |
| engineering and the pertinent safety regulation of DIN EN 60598/1:1996. |
| 2.6 Supply voltage must not exceed the ranges that are given in the "Technical Data" (see |
| page 13). Check that the power supply voltage and wiring are suitable for the ballast to |
| be used. Supply voltages which are greater or less than that specified for the ballast can |
| cause injury to the user as well as damage to the ballast. |
| The electronic of the EB is built in a housing with protective class I and protective rate |
| IP 20. |
| Ambient operating temperatures must be between |
| The air slots for ventilation at front panel and rear side should never be covered or |
| obstructed. |
| The EB must only be placed in a 19" Cabinet Rack or on solid, flat and dry ground. |
| Temperature of the ground should be less than 50°C. If the EB could slip over the |
| ground it must be fastened. |
| Protect EB against direct sunshine. The EB must be protected against splash and drip- |
| water (acc. to protective rate IP 20). |
| Do not operate the EB in high humidity (dew) or in aggressive or explosive |
| mixtures. |