4.Use the arrow key to select the disk you would like to configure as hot spare, then move the cursor to the Hot Spr column. Press <+>, <->, or <Space>. The Drive Status column field now shows Hot Spare.

Press <C> to commit the changes.

LSI Corp Config Utility

v6.20.00.00 (2007.12.04)

Manage Hot Spare -- SAS1064E

 

Identifier

LSILOGICLogical Volume 3000

Type

IME

Scan Order

0

Size(MB)

51498

Status

Optimal

 

Slot

Device Identifier

 

Hot

Drive

Pred

Size

 

Num

 

 

Spr

Status

Fail

(MB)

0

SEAGATE ST336754SS

0003

[No]

Ok

No

34331

1

SEAGATE ST336754SS

0003

[No]

Ok

No

34331

2

SEAGATE ST336754SS

0003

[No]

Ok

No

34331

3

SEAGATE ST336754SS

0003

 

[Yes]

Hot Spare

No

35003

 

 

 

 

 

[----]

---------

--

-----

 

 

 

 

 

 

 

 

 

Esc = Exit Menu F1/Shift+1 = Help

 

 

 

 

 

 

SPACE/+/- = Change Item

C = Commit Changes

 

 

 

 

 

 

 

 

 

 

 

Synchronizing the array

Synchronizing the array allows the utility to resynchronize data on the mirrored disk in the array. This procedure is seldom required because data synchronization is automatically done during normal operation.

To synchronize the array:

1.Follow steps 1–3 of the section Viewing volume properties and step 2 of the section Managing hot spares.

2.From the Manage Array screen select Synchronize Array, then press <Enter>.

 

LSI Corp Config Utility

 

v6.20.00.00 (2007.12.04)

 

 

Manage Array -- SAS1064E

 

 

 

 

 

Identifier

 

LSILOGICLogical Volume 3000

 

 

 

Type

 

IME

 

 

 

Scan Order

0

 

 

 

Size(MB)

51498

 

 

 

Status

 

Optimal

 

 

 

 

 

 

 

 

 

Manage Hot Spare

 

 

 

 

 

Synnchronize Array

 

 

 

 

 

Activate Array

 

 

 

 

 

 

 

 

 

 

 

Delete Array

 

 

 

 

 

 

 

 

 

 

Esc = Exit Menu

F1/Shift+1 = Help

 

 

Enter = Select Item

 

 

 

 

 

 

 

 

 

3.Press <Y> to begin the synchronization, or <N> to cancel.

ASUS PIKE 1064E/1068E

2-15