20.GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS

h.A marine (boat) battery must be removed and charged on shore. To charge it on board requires equipment specially designed for marine use.

20.GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS

The charger should be grounded to reduce the risk of electric shock. This charger is equipped with an electric cord having an equipment grounding conductor and a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.

DANGER. Never alter the AC cord or plug provided - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Improper connection can result in a risk of an electric shock. This battery charger is for use on a nominal 120-volt circuit, and has a grounding plug that looks like the plug illustrated in FIGURE (A). A temporary adapter, which looks like the adapter illustrated in FIGURE (C), may be used to connect this plug to a two-pole receptacle, as shown in FIGURE (B), until a properly grounded outlet can be installed by a qualified electrician.

DANGER. Before using an adapter as illustrated, be certain that the center screw of the outlet plate is grounded.

The green-colored rigid ear or lug extending from the adapter must be connected to a properly grounded outlet - make

certain it is grounded. If necessary, replace the original outlet cover plate screw with a longer screw that will secure the

adapter ear or lug to the outlet cover plate and make ground connection to grounded outlet.

NOTE: USE OF AN ADAPTER IS NOT ALLOWED IN CANADA. IF A GROUNDING TYPE RECEPTACLE IS NOT AVAILABLE, DO NOT USE THIS APPLIANCE UNTIL THE PROPER OUTLET IS INSTALLED BY A QUALIFIED ELECTRICIAN.

21.LENGTH OF CHARGE

a.Test the battery for state of charge. Do not charge if it is over 75% charged or the battery is determined to be defective.

b.Set beginning amps charge rate for size of battery and state of charge per charts

c.Charge for length of time per charge,

d.Discontinue charge when the specific gravity of electrolyte reaches 1.260 or above. A temperature compensating hydrometer should be used for this reading. Discontinue charge if the battery begins to gas excessively or when the temperature of the electrolyte reaches approximately 120EF. Do not overcharge batteries. Overcharging results in excessive water loss and eventual damage to the battery.

ASSEMBLY INSTRUCTIONS

Remove the handle from the back of the charger and attach in a upright position using the four screws provided.

OPERATING INSTRUCTIONS

CAUTION - This battery charger must be fully assembled before operating. Failure to do so may result in risk of injury.

USE OF THE INSTRUMENT PANEL:

The MINUTES CHARGE timer has an OFF position, a CONTINUOUS CHARGE position and a timed charge range from 0 to 90 minutes.

a.OFF - Always make sure the timer is in the OFF position before connecting or disconnecting the clamps from the battery. The