Components
The Local Unit (CE-250L)
Front View:
1
2
|
| AC 9V |
CO | NS |
|
|
| OLE |
3 |
|
|
4 |
| 7 |
| 5 | |
| 6 | |
|
|
1.Operating Mode Selection Switch
Pressing this button toggles between the operating mode choices:
M Local: only the local console can control the system(s);
M Auto: both consoles can control the system(s).
2.LEDs
The Local Unit has two LEDs to indicate the operating status of the Local and Remote units (see p. 9, for details).
3.Mouse Port
The local PS/2 mouse plugs into this connector.
4.Keyboard Port
The local PS/2 keyboard plugs into this connector.
5.Monitor Port
The local monitor plugs into this connector.
6.Remote I/O
The Category 5 twisted pair cable that connects to the Remote Unit plugs into this connector.
7.Power Jack
The cable from the AC Power Adapter plugs into this jack.