Atlona AT-COMP-44M user manual RS-232, Command, Feedback, Description

Models: AT-COMP-44M

1 11
Download 11 pages 49.6 Kb
Page 7
Image 7
RS-232

RS-232

Connection

RS-232 is connected through a 9-pin female D connector. The pins will have functions associated with them, some will be unassigned.

5CommandFeedback 4 DescriptionManual background3 Manual backgroundManual background2 Manual backgroundManual background 1

9 Manual backgroundManual background8 Manual backgroundManual background 7 Manual backgroundManual background 6

Baud Rate: 9600bps

Command

 

 

No.

Pin

 

Function

 

 

 

1

----

 

Not used

 

 

 

2

Tx

 

Transmit

 

 

 

3

Rx

 

Receive

 

 

 

4

----

 

Not used

 

 

 

5

Gnd

 

Ground

 

 

 

6

----

 

Not used

 

 

 

7

----

 

Not used

 

 

 

8

----

 

Not used

 

 

 

9

----

 

Not used

 

 

 

 

 

 

 

 

Data Bit: 8bits

Parity: None

Stop Bit: 1bit

 

The command codes are very sensitive, do not change capitalization, spacing, or lettering.

 

Command

Feedback

Description

 

 

PWON

PWON

Power on

 

 

PWOFF

PWOFF

Power off

 

 

All#

All#

Resets all inputs to corresponding outputs (in3 to out3)

 

 

x1$

x1$

Turns off output channel (to turn off output 3 = x3$)

 

 

x1AVx2

x1AVx2

Switch input to output (input 3 to output 5 = x3AVx5)

 

 

x1AVx2,x3,x4

x1AVx2,x3,x4

Switch input to multiple outputs (input 3 = x3AVx1,x2)

 

 

Statusx1

x7AVx1

Shows what input is connected to selected output

 

 

Status

x1AVx1, x2AVx2,

Displays which inputs are currently connected to which outputs

 

 

 

x3AVx4, ....

 

 

 

Save[Y]

Save2

Saves settings for future use, saves vary from 0 to 9

 

 

Recall[Y]

Recall2

Pulls up saved settings for the number you selected

 

 

Clear[Y]

Clear2

Erases the save for the number you selected

 

 

Mreset

Mreset

Sets matrix back to the default settings

 

 

 

 

 

 

Each command or feedback is terminated with a carriage return.

Note: If the command fails or is incorrect the feedback should be “Command FAILED”

Toll free: 1-877-536-3976

5

atlona.com

Local: 1-408-962-0515

Page 7
Image 7
Atlona AT-COMP-44M user manual RS-232, Command, Feedback, Description