2www.atlona.com
Toll free: 1-877-536-3976
Local: 1-408-962-0515
Conductor Stranded Tinned Copper
Component A: (1 Pair +Drain Wire+ Shield)x7 14C
AWG 24
Construction (mm) 7/0.20T
Stranded Dia.(mm) 0.60
Insulation FOAM FEP
Nom. Thickness (mm) 0.42
Insulation Dia.( ±0.05mm) 1.45
Drain Wire 7/0.20T
Shield E-F-E Aluminum/Polyester
Coverage(%) >=125%
Component B :1P 1P
Conductor Stranded Tinned Copper
AWG 24
Construction (mm) 7/0.20T
Stranded Dia.(mm) 0.60
Insulation FEP
Nom. Thickness (mm) 0.17
Insulation Dia.( ±0.05mm) 0.95
Component C : 3C 3C
Conductor Stranded Tinned Copper
AWG 24
Construction (mm) 7/0.20T
Stranded Dia.(mm) 0.60
Insulation FEP
Nom. Thickness (mm) 0.17
Insulation Dia.( ±0.05mm) 0.95
Component A+B+C Cabling Together Shield
Shield Aluminum/Polyester
Coverage(%) >=125%
Drain Wire(Stranded Tinned Copper) 7/0.20T
Braid Shield Tinned Copper
Construction(mm) 24/9/0.12T
Coverage(%) >=85%
Jacket Plenum-PVC
Nom. Thickness(mm) 0.55
Outer Dia.(± 0.20mm) 10.5
CONSTRUCTION