3. Absolute Maximum Ratings

Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.

Parameters

Symbol

Value

Unit

 

 

 

 

Supply voltage

VCC

5

V

Supply current

Icc

400

mA

Junction temperature

Tj

150

°C

Storage temperature

TStg

–40 to +125

°C

Input RF power

Pin

10

dBm

Control voltage

Vctl

2.5

V

Note: The part may not survive all maximums applied simultaneously.

Electrostatic sensitive device.

Observe precautions for handling.

4. Thermal Resistance

 

 

 

Parameters

Symbol

Value

Unit

 

 

 

 

Junction ambient package QFN16, 3 3,

RthJA

40

K/W

slug soldered on PCB

 

 

 

 

 

 

 

5. Operating Range

Parameters

Symbol

Value

Unit

 

 

 

 

Supply voltage

VCC

2.7 to 3.8

V

Operating frequency range

fin

5100 to 5900

MHz

Ambient temperature range

Tamb

–25 to +75

°C

4ATR7040