3. Absolute Maximum Ratings
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability.
Parameters | Symbol | Value | Unit |
|
|
|
|
Supply voltage | VCC | 5 | V |
Supply current | Icc | 400 | mA |
Junction temperature | Tj | 150 | °C |
Storage temperature | TStg | °C | |
Input RF power | Pin | 10 | dBm |
Control voltage | Vctl | 2.5 | V |
Note: The part may not survive all maximums applied simultaneously.
Electrostatic sensitive device.
Observe precautions for handling.
4. Thermal Resistance |
|
|
| |
Parameters | Symbol | Value | Unit | |
|
|
|
| |
Junction ambient package QFN16, 3 ⋅ 3, | RthJA | 40 | K/W | |
slug soldered on PCB | ||||
|
|
| ||
|
|
|
|
5. Operating Range
Parameters | Symbol | Value | Unit |
|
|
|
|
Supply voltage | VCC | 2.7 to 3.8 | V |
Operating frequency range | fin | 5100 to 5900 | MHz |
Ambient temperature range | Tamb | °C |
4ATR7040