ATTO Technology SC 5300 manual FastStream SC, Power Behind the Storage, Storage Controller

Models: SC 5300

1 2
Download 2 pages 54.5 Kb
Page 2
Image 2
FastStream™ SC 5300

FastStream™ SC 5300

Storage Controller

Technical Features

 

RAID Support

JBOD, DVRAID™, 0, 1, 4, 5, 10, 40, 50 and N-way mirroring

 

 

Key Features

Avid® certified for use with MediaDock™ Ultra320 Storage

 

RAID rebuild with tunable RAID rebuild Priority

 

Latency management for remote editing in audio production environments

 

Drive Performance Metrics

 

Global Hot Spares

 

Drive Initialization and Verification

 

Port Mapping for LUN Isolation

 

Field Upgradeable Firmware

 

O/S Independent Operation

 

Battery Backed Event Log

 

ECC Protected Memory

 

Phone Home Error Notification

 

 

Hardware Specifications

 

Fibre Channel Interface

4 Gigabit, auto-negotiates to 2/1 Gigabit devices

 

Two Optical SFP (Small Form Factor Pluggable) Fibre Channel ports

 

Full support for direct connect for F-port fabric switches

 

Class 3 and Intermix ANSI Fibre Channel Specifications

 

PLDA, public loop login (NL-ports) and fabric connect (N-port)

 

Full-duplex transmissions

 

 

SCSI Interface

Dual independent Ultra320 LVD/SE SCSI bus ports

 

Dual stacked VHDCI SCSI connectors

 

Backwards compatible with all single-ended SCSI devices

 

 

Management Interface

RJ-45 connector for Ethernet management port

 

RS-232 serial header console port

Management

 

Local and Network Management

ExpressNAVTM storage manager browser-based user interface for remote

 

configuration, management and diagnostic capabilities

 

Local diagnostics supported via CLI, Telnet and FTP

 

Command line and menu-based ASCII text management access via the

 

Ethernet management port

Environmental & Physical Specifications

 

Dimensions

1.579” (1U) H x 16.494” W x 10.000” L

 

 

Operating Environment

Temperature: 5 - 40° C Humidity: 10 - 90% non-condensing

 

 

Storage Environment

Temperature: 0 - 40° C Humidity: 20 - 80% non-condensing

 

 

Power

Input: 100-240VAC +/- 18%, 50/60 Hz

 

 

Airflow

11 CFM recommended

 

Ambient air not to exceed 40° C

RoHS Compliant

Yes

 

 

Ordering Information

 

Model Number

FSSC-5300-0R0

 

 

Accessories

Cables: CBL-LCLC-R10 (10M LC-LC cables)

 

 

Technical Specification

FastStream SC 5300

Power Behind the Storage

For More Information:

www.ATTOTech.com

or to Purchase:

www.ATTOStore.com

(716) 691-1999

©2008 ATTO Technology, Inc. Specifications subject to change without notice.