FastStream™ SC 7500

Storage Controller

Technical Features

 

 

RAID Levels

• JBOD, DVRAID, 0, 1, 4, 5, 6*, 10, 40, 50 and 60* plus N-way mirroring

 

 

 

Key Features

• Tunable RAID Rebuild Priority

• Zoning LUN mapping (optional)

 

Real-time Performance Metrics

• One button setups for Audio, Video, IT

 

• Application Performance Reporting

• Field Upgradeable Firmware

 

• Global Hot Spares

• O/S Independent Operation

 

• Audio Latency Management

• Battery Backed Event Log

 

• Drive Initialization and Verification

• ECC Protected Memory

 

• Partitioning of RAID Volumes

• Phone Home email Error Notification

 

• Port Mapping for LUN Isolation

• ExpressNAV™ Storage Manager

 

 

 

Hardware Specifications

 

 

Fibre Channel Interface

4-Gigabit, auto-negotiates to 2/1 Gigabit devices

 

• Four Optical SFP (Small Form Factor Pluggable) Fibre Channel ports

 

• Full support for direct connect for F-port fabric switches

 

• Class 3 and Intermix ANSI Fibre Channel Specifications

 

• PLDA, public loop login (NL-ports) and fabric connect (N-port)

 

Full-duplex transmissions

 

 

 

SAS/SATA Interface

• Eight 3-Gb SAS/SATA ports via two four-port MiniSAS (SFF-8080) connectors

 

 

Management Interface

RJ-45 connector for Ethernet management port

 

RS-232 serial header console port

 

 

 

 

Management

 

 

Setup and Monitoring

• Simplified one-click setup allows for system setup in just minutes

 

• Built in read-only drive performance monitoring allows you to gauge

 

storage performance while host-based applications are in use

Local and Network Management

• ExpressNAVTM storage manager browser-based user interface for remote

 

configuration, management and diagnostic capabilities

 

• Local diagnostics supported via CLI, Telnet and FTP

 

• Command line and menu-based ASCII text management access via the

 

Ethernet management port and ExpressNAV

 

 

 

Environmental & Physical Specifications

 

 

Dimensions

• 1.69” (1U) H x 17.31” W x 9.9” L

 

 

 

Operating Environment

• Temperature: 5 - 40° C Humidity: 10 - 90% non-condensing

 

 

Storage Environment

• Temperature: -40 - 70° C Humidity: 5 - 95% non-condensing

 

 

 

Power

• Input: 100-240 VAC, 2.5A, 47-63 Hz

 

 

 

 

Fixed Airflow

• 11 CFM

 

 

• Ambient air not to exceed 40° C

 

 

 

 

RoHS Compliant

• Yes

 

 

 

 

Ordering Information

 

 

Model Number

FSSC-7500-D00

 

 

 

 

*RAID 6 and 60 planned for Q1 2008

Technical Specification

FastStream SC 7500

Power Behind the Storage

For More Information:

www.ATTOTech.com

or to Purchase:

www.ATTOStore.com

(716) 691-1999

©2008 ATTO Technology, Inc. Specifications subject to change without notice.

Rev 1/08

Page 2
Image 2
ATTO Technology SC 7500 Technical Features, Hardware Specifications, Management, Environmental & Physical Specifications

SC 7500 specifications

ATTO Technology has a long-standing reputation for delivering high-performance storage connectivity solutions, and the SC 7500 is a testament to that legacy. The SC 7500 is a cutting-edge storage controller designed to meet the demanding needs of modern data-intensive environments, such as data centers and cloud storage infrastructures. It offers a plethora of features and technologies that set it apart from its competitors.

One of the primary characteristics of the ATTO SC 7500 is its exceptional performance. With advanced caching algorithms and an optimized throughput, this controller is capable of handling multiple simultaneous data streams without compromising speed or reliability. The SC 7500 supports both Fibre Channel and iSCSI protocols, providing users with flexibility in their network configuration and allowing for seamless integration into existing infrastructures.

The SC 7500 also boasts advanced data management features. Its intelligent data tiering and automated load balancing capabilities ensure that data is stored and accessed in the most efficient manner possible. This optimizes performance while minimizing latency, making it an ideal choice for workloads that demand high-speed access, such as video editing or database transactions.

Security is a paramount consideration for any storage system, and the ATTO SC 7500 addresses this concern with robust encryption options. It supports secure data transmission, safeguarding sensitive information as it travels over networks. Additionally, the controller's built-in redundancy features ensure high availability, providing peace of mind that critical data will remain accessible even in the event of hardware failure.

The user-friendly interface of the SC 7500 simplifies management and monitoring, allowing IT administrators to easily configure and maintain the system. Its comprehensive diagnostic tools help in troubleshooting and performance optimization, ensuring that the storage solution operates at peak efficiency.

In summary, the ATTO Technology SC 7500 is a powerful storage controller designed for mission-critical environments. With its advanced performance capabilities, flexible protocol support, robust security features, and user-friendly management tools, it stands out as a top choice for organizations looking to enhance their data management strategies and storage efficiency. Whether for enterprise-level applications or smaller-scale storage needs, the SC 7500 delivers the reliability and performance required in today’s rapidly evolving data landscape.