FastStream™ SC 7700

Storage Controller

Technical Features

 

 

RAID Levels

JBOD, DVRAID, 0, 1, 4, 5, 6, 10, 40, 50 and 60 plus N-way mirroring

 

 

 

Key Features

Tunable RAID Rebuild Priority

SCSI Enclosure Services (SES)

 

Real-time Performance Metrics

Configurable Sector Sizes to 8KB

 

Application Performance Reporting

Field Upgradeable Firmware

 

Local and Global Hot Spares

Hot Swap with Auto Rebuild

 

Configuration Cloning

Battery Backed Event Log

 

Drive Initialization and Verification

ECC Protected Memory

 

Partitioning of RAID Volumes

Advanced Error Handling

 

Port Mapping for LUN Isolation

One button setups for Audio, Video, IT

 

 

 

Hardware Specifications

 

 

Fibre Channel Interface

4-Gigabit, auto-negotiates to 2/1 Gigabit devices

 

Two Optical SFP (Small Form Factor Pluggable) Fibre Channel Host Ports

 

Two Optical SFP Fibre Channel Device Ports

 

Full support for direct connect for F-port fabric switches

 

Class 3 and Intermix ANSI Fibre Channel Specifications

 

PLDA, public loop login (NL-ports) and fabric connect (N-port)

 

Full-duplex transmissions

 

 

 

Management Interface

RJ-45 connector for Ethernet management port

 

RS-232 serial header console port

 

 

 

 

Management

 

 

Setup and Monitoring

Simplified one-click setup allows for system setup in just minutes

 

Built in read-only drive performance monitoring allows you to gauge

 

storage performance while host-based applications are in use

Local and Network Management

ExpressNAVTM storage manager browser-based user interface for remote

 

configuration, management and diagnostic capabilities

 

Local diagnostics supported via CLI, Telnet and FTP

 

Command line and menu-based ASCII text management access via the

 

Ethernet management port

 

 

 

 

Environmental & Physical Specifications

 

 

Dimensions

1.69” (1U) H x 17.31” W x 9.9” L

 

 

 

Operating Environment

Temperature: 5 - 40° C Humidity: 10 - 90% non-condensing

 

 

Storage Environment

Temperature: -40 - 70° C Humidity: 5 - 95% non-condensing

 

 

 

Power

Input: 100-240 VAC, 2.5A, 47-63 Hz

 

 

 

 

Airflow

11 CFM recommended

 

 

Ambient air not to exceed 40° C

 

 

 

 

RoHS Compliant

Yes

 

 

 

 

Ordering Information

 

 

Model Number

FSSC-7700-D00

 

 

 

 

Technical Specification

FastStream SC 7700

Power Behind the Storage

For More Information:

www.ATTOTech.com

or to Purchase:

www.ATTOStore.com

(716) 691-1999

©2008 ATTO Technology, Inc. Specifications subject to change without notice.