64
You must use a SaveConfiguration Restart command to implement the rebuild priority command.

To synchronize mirrored drives manually

1 Connect to Diamond Storage Array services via
the RS-232 port or the optional Ethernet
management services card (refer to
Accessing
the Array
on page 17). You should now be in
CLI.
2 Continue with the CLI or access the RAID page
of the ExpressNAV interface (refer to
ATTO
ExpressNAV: Browser-based Interface
on page 25).
3 If AutoRebuild has not been disabled, type
set AutoRebuild disabled saveconfiguration
restart.
4 After the array reboots and completes its
diagnostics, enter the CLI and type
RAIDManualRebuild L S where L is the LUN
and S is the sled to be rebuilt.
This procedure may take a few hours,
depending on the size of the LUN.
5 To check the rebuild status, type

RAIDRebuildStatus