![FastStream VT 5300](/images/new-backgrounds/114962/1149623x1.webp)
FastStream VT 5300
Virtual Tape Appliance
Technical Features |
|
|
|
Virtual Tape Library | • Virtual Libraries Supported: 2 |
| |
| • Maximum Virtual Tape Drives per Library: 30 |
| |
| • Maximum Virtual Tapes per Library: 256 |
| |
| • |
| |
| • All required tape and media changer commands supported |
| |
|
|
| |
RAID Levels | • 0, 1, 5 and 10 (JBOD is also supported) with Global Hot Spares |
| |
|
|
| |
Key Features | • RAID Rebuild with Tunable Rebuild Priority |
| |
| • |
| |
| • Advanced VTL Capacity Expansion (AVCE™) Technology |
| |
| • Drive Initialization and Verification, Drive Performance Metrics |
| |
| • Can be shared in heterogeneous environments |
| |
| • SpeedWrite™ |
| |
| • Field Upgradeable Firmware |
| |
| • O/S independent operation |
| |
| • Battery Backed Event Log |
| |
| • ECC Protected Memory |
| |
|
|
|
|
Hardware Specifications |
|
|
|
Fibre Channel Interface | • 4 Gigabit, |
| |
| • Two Optical SFP (Small Form Factor Pluggable) Fibre Channel ports |
| |
| • Class 3 and Intermix ANSI Fibre Channel Specifications |
| |
| • PLDA, public loop login |
| |
| • |
| |
|
|
| |
SCSI Interface | • Dual independent Ultra320 LVD/SE SCSI bus ports |
| |
| • Dual stacked VHDCI SCSI connectors |
| |
| • Backwards compatible with all |
| |
|
|
| |
Management Interface | • |
| |
| • |
| |
|
|
|
|
Management |
|
|
|
Local and Network Management | • ExpressNAVTM VTL manager |
| |
| configuration, management and diagnostic capabilities |
| |
| • Local diagnostics and configuration supported via CLI, Telnet and FTP |
| |
| • Command line ASCII text management access via the Ethernet port |
| |
|
|
|
|
Environmental & Physical Specifications |
|
|
|
Dimensions | • 1.579” (1U) H x 16.494” W x 10.000” L |
| |
|
|
| |
Operating Environment | • Temperature 5 - 40° C ● Humidity: 10 - 90% |
| |
|
|
| |
Storage Environment | • Temperature 0 - 40° C ● Humidity: 20 - 80% |
| |
|
|
| |
Power | • Input: |
| |
|
|
| |
Airflow | • 11 CFM recommended ● Ambient air not to exceed 40° C |
| |
|
|
| |
RoHS Compliant | • Yes |
| |
|
|
|
|
Ordering Information |
|
|
|
Model Number | • |
| |
|
|
| |
Accessories | • FC Cables: |
| |
| • SCSI Cables: |
| |
|
|
|
|
|
|
| For More Information: |
|
|
| www.ATTOTech.com |
|
|
| |
Technical Specification |
| Power Behind the Storage | or to Purchase: |
| www.ATTOStore.com | ||
FastStream VT 5300 |
|
| (716) |
|
|
©2008 ATTO Technology, Inc. Specifications subject to change without notice. | Rev 2/08 |