RC840T
Installation Guide
On/Off Switching Electric Heating Relay with
nApplication
The RC840T Electric Heating Relay is designed to control a line voltage resistive load from a low voltage thermostat. The RC840T relay has a
The RC840T operates silently and can be installed in bedrooms, living rooms, or any other occupied area without disturbing occupants. On a call for heat, the relay is immediately activated; there is no delay. This increases temperature control and comfort.
pOnce mounting and wiring have been completed, return power to the heating system and test the installation.
qIncrease the thermostat temperature to activate the relay. Allow system operation long enough to proof installation. Once installation has been proofed, set temperature to normal setpoint.
pTypical Wiring Diagrams
NOTE: Not recommended for
I
oInstallation
The RC840T must be installed in an area where the temperature is between
The RC840T can be installed on the side of an electrical box or a distribution panel or inside the wiring compartment of an electric baseboard.
Load
Junction box | |
| |
thermostat | Red |
| |
| Black |
| Blue |
You must provide an overload protection and disconnect as required.
Figure 1 : Connection to a
For proper installation, use a screw and a washer.
On the side of | Inside the wiring compartment |
an electrical box | of a baseboard |
Load
Junction box
Red
Black
Blue
All wiring must comply with national and local electrical code regulations.
Installation should be carried out by an electrician. Disconnect power supply before installing the relay to prevent electrical shock.
nSecure relay to the mounting surface using the two mounting brackets. Use the supplied lock nut to secure the relay to the junction box.
oWire the relay and connect according to typical wiring diagrams (refer to figures 1 & 2).
You must provide an overload protection and disconnect as required.
Figure 2 : Connection to a
RC840T | 17/1/07 | 1/2 |