Installation Guide
4
Installation in a baseboard heaterELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect AC power before
beginning installation.
Wiring must comply with local electrical codes. Use special CO/ALR solderless connectors if
supply wires are made of aluminum.
Disconnect the heater wires from the supply wires. If the heater has a built-in thermostat, remove it.
1) Remove the knockout on the side of the heater.
2) Remove the locknut from the antenna and peel off
the adhesive backing. Feed the antenna cable
through the knockout and install the antenna
vertically as shown. Put the locknut and tighten.
3) Clean the back panel inside the wiring
compartment where the relay will be installed. Peel
the adhesive backing off the relay and stick the
relay on the back panel.
4) Connect the heater wires and the supply wires to
the relay.
See page 6 if you are connecting more than one
heater.
5) Insert the antenna plug into the relay receptacle
until you hear a click.
6) Put the heater cover back. (If a built-in thermostat
was removed, install one of the supplied plugs to
cover the hole on the existing cover.) Apply power
to the heater. Do not install the antenna cover yet.
ELECTRICAL HAZARD
Can cause electrical shock. Install heater cover
plate before applying power.
Relay wires must be at the top
L2 L1 : For 240V application
N L : For 120V application
BlueBlue
BlackBlack
RedRed
Install plug if
applicable.
69-2472EF-01 (Aube TA7210 System Installation Guide).book Page 4 Wednesday, June 29, 2011 1:15 PM