pTemperature Display and Setting

The thermostat normally displays the actual (ambi- ent) temperature.

• To view the setpoint temperature, press once on either temperature adjustment button. The icon

appears during the setpoint display.

To change the setpoint temperature, press the appropriate but- ton until the desired value is displayed.

qPower Outage

During a power outage, the setpoint is saved in memory. You do not need to adjust the temperature when power returns.

rSpecifications

-Supply: 120/240 VAC, 50/60 Hz

-Minimum load: 2 A (resistive only) 500 W @ 240 VAC 250 W @ 120 VAC

-Maximum load: 12.5 A (resistive only) 3000 W @ 240 VAC 1500 W @ 120 VAC

-Display range: 0 °C to 50 °C (32 °F to 122 °F)

-Setpoint range: 5 °C to 30 °C (40 °F to 85 °F)

-Storage: -20 °C to 50 °C (-4 °F to 120 °F)

-Approval: c UL us

sTroubleshooting

PROBLEM

SOLUTIONS

 

 

 

This is normal. Under normal operation, the

Thermostat is hot.

thermostat housing can reach a temperature

 

between 35 °C (95 °F) and 40 °C (104 °F).

 

 

 

Correct if any the following conditions

 

applies:

Displayed tempera-

• The thermostat is exposed to air draft.

ture is wrong.

• The sticker on the thermostat’s screen

has not been removed.

 

 

• The thermostat is located near or above

 

a heat source such as a light dimmer.

 

 

 

The thermal protection device on the heater

Display disappears

has temporarily opened. This can happen if

and reappears after

the heater is obstructed by furniture or curtain

a few minutes.

and has overheated, or if the heater’s thermal

 

protection device is too sensitive.

 

 

Display looks faded

The heating system is less than the required

when heating is

minimum load. This thermostat cannot be

activated.

used below that rating.

 

 

;Warranty

Aube warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of three (3) year from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Aube shall repair or replace it (at Aube's option).

If the product is defective,

(i)return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or

(ii)contact Aube. Aube will make the determination whether the product should be returned, or whether a replacement product

can be sent to you.

This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Aube that the defect or mal- function was caused by damage which occurred while the product was in the possession of a consumer.

Aube's sole responsibility shall be to repair or replace the product within the terms stated above. AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCI- DENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WAR- RANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some provinces, states or regions do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.

THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANT- ABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY. Some provinces, states or regions do not allow limita- tions on how long an implied warranty lasts, so the above limitation may not apply to you.

This warranty gives you specific legal rights, and you may have other rights which vary from one province, state or region to another.

Customer assistance

If you have any questions about the product installation or operation, or concerning the warranty, contact us at:

705 Montrichard Saint-Jean-sur-Richelieu, Quebec J2X 5K8

Canada

Tel.: (450) 358-4600

Toll-free: 1-800-831-AUBE

Fax: (450) 358-4650

Email: aube.service@honeywell.com

For more information on our products, go to

www.aubetech.com

TH108

400-108-002-C

5/16/06

2/2

Page 2
Image 2
Aube Technologies TH108 manual Temperature Display and Setting, Power Outage, Specifications, Troubleshooting, Warranty