PB112
Installation Instructions
For models: 120GA / 120GB / 120S / 240GA / 240GB / 240S / 240D
nParts
nOne (1) power base
oTwo (2) screws
pFour (4) solderless connectors for copper wires
NOTE: Special CO/ALR solderless connectors must be used for connecting aluminum conductors.
qOne (1) floor sensor and one (1) flat tip screwdriver (F and AF floor heating models only).
oGuidelines
Turn off power to the heating system at the main electrical panel to avoid electrical shock. The installation should be carried out by an elec- trician.
High voltage thermostats must be installed onto an electrical box.
For a new installation, choose a location about 5 ft. above the floor and on an inside wall.
The thermostat must be installed on an inside wall facing the heating system (except for floor heating systems).
Avoid locations where there are air drafts (top of staircase, air outlet), dead air spots (behind a door), direct sunlight or concealed chimneys or stove pipes (except for floor heating systems).
pProcedure
nConnect the power base wires to the power supply and load using sold- erless connectors for copper wires (figure 1).
oIf your thermostat is type F or AF (not A), insert the floor sensor wires
through one of the two holes below the terminals (figure 2) and connect the wires to terminals 3 and 4 (no polarity).
The wires must run alongside the terminals and not go over them. The wire must not cross any heating wires nor be placed directly on a heating wire or adjacent to it. For best performance, the sensor probe should be centered between the wires in the mat.
pIf you wish to use a remote controller such as the CT240 or CT241,
insert the cable (use 18 to 22 gauge flexible wires) into one of the two holes available below the terminal board and connect to terminals 1 and 2 of the base (figure 2).
qPush the excess length of the
rSecure the power base to the electrical box using the provided screws.
sIf necessary, set the configuration switches on the control module (refer to the control module user guide).
tInstall the control module onto the base. u Apply power to heating system.
Figure 1 | Power |
|
Load
Figure 2
qTechnical Specifications
Model | Supply | Max. Load | Power | Wiring | GFCI | |
|
|
|
|
|
| |
120GA | 120 VAC, 50/60Hz | 15 A | 1800 W | 4w/DP | 5 mA | |
|
|
|
|
|
| |
120GB | 120 VAC, 50/60Hz | 15 A | 1800 W | 4w/DP | 30 mA | |
|
|
|
|
|
| |
120S | 120 VAC, 50/60Hz | 16.7 A | 2000 W | 4w/SP |
| |
|
|
|
|
|
| |
240GA | 240 VAC, 50/60Hz | 15 A | 3600 W | 4w/DP | 5 mA | |
208 VAC, 50/60Hz | 3120 W | |||||
|
|
|
| |||
|
|
|
|
|
| |
240GB | 240 VAC, 50/60Hz | 15 A | 3600 W | 4w/DP | 30 mA | |
208 VAC, 50/60Hz | 3120 W | |||||
|
|
|
| |||
|
|
|
|
|
| |
240S | 240 VAC, 50/60Hz | 16.7 A | 4000 W | 4w/SP |
| |
208 VAC, 50/60Hz | 3475 W |
| ||||
|
|
|
| |||
|
|
|
|
|
| |
240D | 240 VAC, 50/60Hz | 15 A | 3600 W | 4w/DP |
| |
208 VAC, 50/60Hz | 3120 W |
| ||||
|
|
|
| |||
|
|
|
|
|
|
Storage:
Remote controller input (ECONO): requires a dry contact
Size (H • W • D): 4.89 x 2.76 x 0.91 in. (124 x 70 x 23 mm)
Certifications: | Models: | Models: |
120 GA / GB | 120S / 240S | |
| 240 GA / GB | 240D |
PB112 | 1/6/05 | 1/1 |