Thank you for choosing the Aube TH132, a programma- ble thermostat that provides both energy savings and total comfort.

TH132 Description

nDAY/HOUR/MIN—Set the day and clock settings. o PGM—Program the schedule (programs).

pMODE—Select the operating mode. RETURN—To exit a function.

qTo configure temperature setpoints:

Owner’s Guide Comfort, TH132 Description Economy and Models Overview Vacation.

rAdjust the floor temperature limit (AF only). s TH132-ATH132-AF —Increase and decrease temperature.

tTH132-FConfigure the SwitchesEarly StartTemperature DisplayInstall the Control ModuleFirst Power ONFor Floor Heating Installations: Set the Time and Day—Indicates the number of the current program when Automatic mode is enabled.

uCurrent operating mode (auto Adjust the Temperature Setpoints / manual Comfort  and Economy  Setpoints ). In Auto mode, the program’s associated setpoint icon is

also displayed ( Vacation SetpointFloor Temperature Setpoint (AF model only)).

vIndicates the room OR floor temperature.

wHeating indicators (see “Temperature Control” below).

Models Overview

TH132-A

This model has been designed to control a room’s ambi- ent temperature.

The TH132-A has one temperature sensor located in the control module.

TH132-AF

This model is designed to use a floor sensor to control the room temperature.

The TH132-AF has two temperature sensors:

The first one, installed in the control module, controls the ambient temperature.

The second one, installed in the floor (and connected to the power base), limits the temperature of the floor (the default setting of this limit is 82°F).

TH132-F

This model is designed to control floor heating systems.

The TH132-F has one temperature sensor installed in the floor (sensor is connected to the power base).

Configure the Switches

The TH132 has two switches, located on the upper-left part on the rear of the control module, which are used to set the following options:

Early Start

When the Early Start function is enabled (disabled by default), the TH132 calculates the optimum system start time to obtain the desired temperature by the set time. To enable this function:

Position switch #1 down.

Note: When this function is enabled, the system can be activated before the pro- gram’s start time.

Temperature Display

By default, the TH132 displays the temperature in °C. If you wish to change to °F:

Position switch #2 up.

Note: When you switch from °C to °F or vice

versa, the Select the Operating Mode, Manual background and Manual background setpoints must be redefined.

Install the Control Module

Align the bracket tabs on the control module with the holes located on top of the power base.

This control module must be installed on a PB130 series power base.

Control module

Air vents

Air vents

Power base

Note: Keep the thermostat's air vents clean and free from obstructions.

Note: The screw cannot be removed completely.

First Power ON

On the first installation, the screen displays: 0:00, MO, Manual background and temperature (room/floor).

For Floor Heating Installations:

One of the two following messages may be dis- played when a problem occurs:

LO: The floor temperature is below 32°F (0°C), or the temperature sensor is defective, or not connected.

The heating indicator Manual backgroundManual backgroundManual background is displayed and the relay is closed (energized).

HI: The floor temperature is above

140°F (60°C), or the temperature sensor is defective.

Manual background Set the Time and Day

n Set the time (HOUR - MIN). o Set the day (DAY).

If you remove the module from its base for more than 2 hours, the time and day will have to be reprogrammed.

Adjust the Temperature Setpoints

Comfort Manual background and Economy Manual background Setpoints

These setpoints are associated with the schedule’s pro- grams (prog. 1 & 3 = Comfort, prog. 2 & 4 = Economy) and are preprogrammed as follows:

A & AF models— Manual background 68°F, Manual background 64°F F model— Manual background 82°F, Manual background 68°F

To modify a setpoint:

nSet the temperature using Manual backgroundManual background and press and hold the

Manual background or Manual background button until it is displayed on the screen.

oPress MODE/RETURN to exit.

Vacation Setpoint

The vacation setpoint is associated to the Vacation oper- ating mode and is preprogrammed to 50°F. To modify this setpoint, repeat above steps.

Floor Temperature Setpoint (AF model only)

The floor temperature limit is preprogrammed to 82°F to avoid damage to your floor.

To modify, press the adjustment button (below Manual background) using a pointed object, set the desired temperature using Manual backgroundManual background and press MODE/RETURN to exit.

Select the Operating Mode

The TH132 offers three operating modes:

Automatic Manual backgroundExecutes the schedule.

n Press MODE to select

. The current

program number is displayed.

You can temporarily

bypass the current

program by setting a specific temperature setpoint

or by selecting one of the pre-defined setpoint

buttons ( Manual backgroundManual background ). The new setpoint will be maintained until the beginning of the next program. Manual background

Manual Manual background —Maintains a constant temperature. n Press MODE to select Manual background .

oSet temperature Manual backgroundManual background or select one of the pre- Manual background

defined setpoint buttons ( Manual backgroundManual background ).

Vacation Manual background—Maintains the Vacation setpoint during a prolonged absence.

Press Manual background.

400-132-000-A

Page 1
Image 1
Aube Technologies TH132 A/F/AF manual TH132 Description, Models Overview, Configure the Switches, First Power ON, TH132-A