2.3Pump Protection

For hot water installations, it is recommended to activate the pump at least one minute every 24 hours in order to avoid seizure. Place switch #3 down to activate this function.

For all other installations, leave switch #3 in the Off position (otherwise your system will be activated 1 minute every 24 hours).

2.4Temperature in °C or °F

The TH135 is factory-set to °C. If you wish to change the temperature display to °F, slide switch #4 upward. Please note that if you change from °C to °F or vice versa, you must reset the Comfort (), Economy ( ) and

Vacation ( ) settings accordingly.

pBattery Installation

Appears when the

setpoint is displayed Temperature display

Percentage

of heating * Preset temperature icon

*The thermostat displays the percentage of heating required to maintain the desired tem- perature. For example, is displayed when heating is activated at 40 percent.

Display

 

% of heating

1 to 24% 25 to 49% 50 to 74% 75 to 99% 100%

When you first install the batteries in the TH135, the unit runs a sequence of tests for approximately 5 seconds. After the tests, the screen should display the current temperature.

It is normal for the displayed temperature to be higher than the room temperature if you are holding the TH135 in your hands. It will return to normal about one hour after installation on the wall.

Mount the thermostat on the wall plate and screw it in place.

qTemperature Settings

Preset Temperature

Default Setting

Comfort temperature

20 °C (68 °F)

Economy temperature

18 °C (64 °F)

Vacation temperature

10 °C (50 °F)

nTo set the Comfort temperature, select the desired degree using

the buttons and push the button until the icon is displayed (about 3 seconds).

oTo set the Economy temperature, select the desired degree

using the buttons and push the button until the icon is displayed about 3 seconds).

pTo set the Vacation temperature, select the desired degree using

the buttons and push simultaneously the and buttons until the icon is displayed (about 3 seconds). This setting is used by the telephone controller.

rTelephone Controller

The TH135 incorporates a telephone controller interface which allows you to switch from the or setting to the Vacation setting

(), and vice versa using a touchtone telephone. You can, for example, start the heating of your secondary residence from your office on Friday, or your house from the airport or from your car on your way back from vacation.

5.1Connection to the CT240

The TH135 is designed to connect directly to the CT240 telephone controller. This combination allows the activation and deactivation of the Vacation setting from the CT240 or telephone.

Connect the CT240’s terminals A and C to the TH135's terminals X and C respectively. You must respect the polarity.

For details on operating the telephone controller, refer to the CT240’s instruction manual.

5.2Operating the Telephone Interface

You can activate the Vacation setting using the Vacation button of the telephone controller () or using a telephone from outside of the house.

nTo activate the Vacation setting, press the Vacation button of the CT240 (). The Vacation setting will be displayed for 5 seconds

and the () icon will flash on the screen. You no longer have access to the TH135 keypad if this function is activated by the telephone controller.

oTo deactivate the function and return to the previous setting, press the Vacation button of the telephone controller again or

use a phone. The red light will go off and the () icon will disappear within 5 seconds.

sConnection to a Home Automation System

The Vacation setting can also be activated from a home automation system.

tBattery Replacement

The TH135 will display an icon indicating that the batteries must be replaced. This icon will flash for 60 days. After this period, the thermostat will shut down your heating unit.

After the battery replacement, you have to reprogram the , and settings (refer to section 4).

Even if the thermostat indicates the batteries are good, it is recommended to replace them once a year at the beginning of the heating season.

TH135-01

400-135-000-B

11/12/06

2/3

Page 2
Image 2
Aube Technologies TH135-01 manual Battery Installation, Temperature Settings, Telephone Controller, Battery Replacement