Aube Technologies TH149 p Configuration Menu, q Operation, r Technical Specifications, s Warranty

Models: TH149

1 2
Download 2 pages 11.86 Kb
Page 2
Image 2
pConfiguration Menu

pConfiguration Menu

The configuration parameters appear in the order shown below.

PARAMETERS

DEFAULT

OPTIONS

 

 

 

Temperature display

°C

°C or °F

Heating cycles per hour 1

4

2, 3, 4, 5 or 6 2

Cooling cycles per hour 1

4

2, 3, 4, 5 or 6 2

System type

2H

2H (2H1C) or 1H (1H1C)

1H1C type 3

HP

HP (Heat Pump) or Cn (HVAC)

1When either the heating or the cooling parameter is displayed, use the mode selector switch to toggle between the two parameters.

2The corresponding cycle lengths are: 2 = 30 min., 3 = 20 min., 4 = 15 min., 5 = 12 min., 6 = 10 min.

3This parameter appears only if you select 1H1C for the system type.

nTo access the configuration menu, press and hold both temperature adjustment buttons for more than 3 seconds.

oTo go to the next parameter, once in the menu, press both temperature adjustment buttons for more than 2 seconds.

pTo modify the displayed parameter, press one of the temperature adjust- ment buttons.

qYou will exit the configuration menu at the end of the menu.

Note: The settings are not erased during a power outage.

qOperation

4.1 System Mode

Use the system mode selector switch to place the system in heat mode, cool mode, emergency heat (E.H.) mode, or off.

Note: Emergency heat mode is not available on 1H1C systems. For these systems, placing the selector on E.H. is the same as placing it on Off.

Auxiliary Heat

Only 2H1C systems are equipped with auxiliary heat. The auxiliary heat is used in the following conditions:

When the setpoint is not attained after a 15-minute delay following the compressor activation. After the delay, the auxiliary heating is used along with the compressor.

When the thermostat is placed in emergency heating (E.H.). In this mode, only the auxiliary heat is used.

4.2 Fan Mode

Use the fan mode selector switch to place the fan in automatic mode (AUTO) or continuous mode (ON).

Note: This switch is not functional if the fan is not connected to the thermostat.

AUTO

The fan operates only when heating or cooling is activated.

 

 

ON

The fan operates continuously.

 

 

4.3 Viewing and Setting the Temperature

The actual temperature is normally displayed. To view the setpoint, press once on one of the temperature adjustment buttons. The setpoint is displayed

for 5 seconds and is indicated by the PARAMETERS icon display. To change the setpoint, press the appropriate temperature adjustment button during the setpoint dis- play.

4.4 Backlight

The display illuminates for 12 seconds when either of the temperature adjust- ment buttons is pressed.

4.5 Setpoint Lock

A switch on the back of the front module can be used to lock the setpoint.

nRemove the front module from the

back plate to access the switch.

oPlace the switch (S1) to the I posi- tion.

pReinstall the front module.

rTechnical Specifications

Power supply: 24 VAC

Maximum load: 1.5 A per output @ 24 VAC

Setpoint range (heat): 5 to 28°C (41 to 82°F)

Setpoint range (cool): 15 to 35°C (59 to 95°F)

Setpoint increment: ± 0.5°C (1°F)

Display range: -5 to 50°C (23 to 122°F)

Display resolution: 0.5°C (1°F)

Short-cycle protection: 2 minutes

Storage temperature: -20 to 50°C (-2 to 122°F)

Dimensions: 79 mm x 81 mm x 25 mm (3.1 in. x 3.2 in. x 1.0 in.)

sWarranty

Aube warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of three (3) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Aube shall repair or replace it (at Aube's option).

If the product is defective,

(i)return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or

(ii)contact Aube. Aube will make the determination whether the product should be returned, or whether a replacement product can be sent to you.

This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Aube that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer.

Aube's sole responsibility shall be to repair or replace the product within the terms stated above. AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some provinces and states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.

THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS WARRANTY. Some provinces and states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

This warranty gives you specific legal rights, and you may have other rights which vary by province, state or region.

tTechnical Support

For any questions regarding product installation or operation, contact our technical support team at:

705, Montrichard Saint-Jean-sur-Richelieu, Quebec J2X 5K8

Canada

Tel.: (450) 358-4600

Toll-free: 1-800-831-AUBE

Fax: (450) 358-4650

Email: service@aubetech.com

For more information on our products, visit us at

www.aubetech.com

TH149

400-149-000-B

10/5/05

2/2